Improved Mounting of Strain Sensors by Reactive Bonding

Aim of this work is to improve the bond between a strain sensor and a device on which the strain shall be determined. As strain sensor, a CMOS-integrated chip featuring piezoresistive sensor elements was used which is capable of wireless energy and data transmission. The sensor chip was mounted on a...

Descripción completa

Detalles Bibliográficos
Autores principales: Schumacher, Axel, Shah, Vraj, Steckemetz, Stefan, Dietrich, Georg, Pflug, Erik, Hehn, Thorsten, Knappmann, Stephan, Dehé, Alfons, Leson, Andreas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8288070/
https://www.ncbi.nlm.nih.gov/pubmed/34305376
http://dx.doi.org/10.1007/s11665-021-05993-w
_version_ 1783724028989538304
author Schumacher, Axel
Shah, Vraj
Steckemetz, Stefan
Dietrich, Georg
Pflug, Erik
Hehn, Thorsten
Knappmann, Stephan
Dehé, Alfons
Leson, Andreas
author_facet Schumacher, Axel
Shah, Vraj
Steckemetz, Stefan
Dietrich, Georg
Pflug, Erik
Hehn, Thorsten
Knappmann, Stephan
Dehé, Alfons
Leson, Andreas
author_sort Schumacher, Axel
collection PubMed
description Aim of this work is to improve the bond between a strain sensor and a device on which the strain shall be determined. As strain sensor, a CMOS-integrated chip featuring piezoresistive sensor elements was used which is capable of wireless energy and data transmission. The sensor chip was mounted on a standardized tensile test specimen of stainless steel by a bonding process using reactive multilayer systems (RMS). RMS provide a well-defined amount of heat within a very short reaction time of a few milliseconds and are placed in-between two bonding partners. RMS were combined with layers of solder which melt during the bonding process. Epoxy adhesive films were used as a reference bonding process. Under mechanical tensile loading, the sensor bonded with RMS shows a linear strain sensitivity in the whole range of tested forces whereas the adhesive-bonded sensor has slightly nonlinear behavior for low forces. Compared to the adhesive-bonded chips, the sensitivity of the reactively bonded chips is increased by a factor of about 2.5. This indicates a stronger mechanical coupling by reactive bonding as compared to adhesive bonding.
format Online
Article
Text
id pubmed-8288070
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-82880702021-07-19 Improved Mounting of Strain Sensors by Reactive Bonding Schumacher, Axel Shah, Vraj Steckemetz, Stefan Dietrich, Georg Pflug, Erik Hehn, Thorsten Knappmann, Stephan Dehé, Alfons Leson, Andreas J Mater Eng Perform Article Aim of this work is to improve the bond between a strain sensor and a device on which the strain shall be determined. As strain sensor, a CMOS-integrated chip featuring piezoresistive sensor elements was used which is capable of wireless energy and data transmission. The sensor chip was mounted on a standardized tensile test specimen of stainless steel by a bonding process using reactive multilayer systems (RMS). RMS provide a well-defined amount of heat within a very short reaction time of a few milliseconds and are placed in-between two bonding partners. RMS were combined with layers of solder which melt during the bonding process. Epoxy adhesive films were used as a reference bonding process. Under mechanical tensile loading, the sensor bonded with RMS shows a linear strain sensitivity in the whole range of tested forces whereas the adhesive-bonded sensor has slightly nonlinear behavior for low forces. Compared to the adhesive-bonded chips, the sensitivity of the reactively bonded chips is increased by a factor of about 2.5. This indicates a stronger mechanical coupling by reactive bonding as compared to adhesive bonding. Springer US 2021-07-19 2021 /pmc/articles/PMC8288070/ /pubmed/34305376 http://dx.doi.org/10.1007/s11665-021-05993-w Text en © ASM International 2021 This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic.
spellingShingle Article
Schumacher, Axel
Shah, Vraj
Steckemetz, Stefan
Dietrich, Georg
Pflug, Erik
Hehn, Thorsten
Knappmann, Stephan
Dehé, Alfons
Leson, Andreas
Improved Mounting of Strain Sensors by Reactive Bonding
title Improved Mounting of Strain Sensors by Reactive Bonding
title_full Improved Mounting of Strain Sensors by Reactive Bonding
title_fullStr Improved Mounting of Strain Sensors by Reactive Bonding
title_full_unstemmed Improved Mounting of Strain Sensors by Reactive Bonding
title_short Improved Mounting of Strain Sensors by Reactive Bonding
title_sort improved mounting of strain sensors by reactive bonding
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8288070/
https://www.ncbi.nlm.nih.gov/pubmed/34305376
http://dx.doi.org/10.1007/s11665-021-05993-w
work_keys_str_mv AT schumacheraxel improvedmountingofstrainsensorsbyreactivebonding
AT shahvraj improvedmountingofstrainsensorsbyreactivebonding
AT steckemetzstefan improvedmountingofstrainsensorsbyreactivebonding
AT dietrichgeorg improvedmountingofstrainsensorsbyreactivebonding
AT pflugerik improvedmountingofstrainsensorsbyreactivebonding
AT hehnthorsten improvedmountingofstrainsensorsbyreactivebonding
AT knappmannstephan improvedmountingofstrainsensorsbyreactivebonding
AT dehealfons improvedmountingofstrainsensorsbyreactivebonding
AT lesonandreas improvedmountingofstrainsensorsbyreactivebonding