Cargando…
RNase H-dependent amplification improves the accuracy of rolling circle amplification combined with loop-mediated isothermal amplification (RCA-LAMP)
The hybrid method upon combining rolling circle amplification and loop-mediated isothermal amplification (RCA-LAMP) was developed to quantify very small amount of different type of RNAs, such as miRNAs. RCA-LAMP can help detect short sequences through padlock probe (PLP) circularization and exhibit...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
PeerJ Inc.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8327969/ https://www.ncbi.nlm.nih.gov/pubmed/34395086 http://dx.doi.org/10.7717/peerj.11851 |
_version_ | 1783732213535211520 |
---|---|
author | Hasegawa, Takema Hapsari, Diana Iwahashi, Hitoshi |
author_facet | Hasegawa, Takema Hapsari, Diana Iwahashi, Hitoshi |
author_sort | Hasegawa, Takema |
collection | PubMed |
description | The hybrid method upon combining rolling circle amplification and loop-mediated isothermal amplification (RCA-LAMP) was developed to quantify very small amount of different type of RNAs, such as miRNAs. RCA-LAMP can help detect short sequences through padlock probe (PLP) circularization and exhibit powerful DNA amplification. However, one of the factors that determines the detection limit of RCA-LAMP is non-specific amplification. In this study, we improved the accuracy of RCA-LAMP through applying RNase H-dependent PCR (rhPCR) technology. In this method, the non-specific amplification was suppressed by using the rh primer, which is designed through blocking the modification at the 3′end to stop DNA polymerase reaction and replacing the 6th DNA molecule from the end with RNA using RNase H2 enzyme. Traditional RCA-LAMP amplified the non-specific amplicons from linear PLP without a targeting reaction, while RCA-LAMP with rh primer and RNase H2 suppressed the non-specific amplification. Conversely, we identified the risk posed upon conducting PLP cyclization reaction using Splint R ligase in the RNA-targeting step that occurred even in the RNA-negative condition, which is another factor determining the detection limit of RCA-LAMP. Therefore, this study contributes in improving the accuracy of RNA quantification using RCA-LAMP. |
format | Online Article Text |
id | pubmed-8327969 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | PeerJ Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-83279692021-08-13 RNase H-dependent amplification improves the accuracy of rolling circle amplification combined with loop-mediated isothermal amplification (RCA-LAMP) Hasegawa, Takema Hapsari, Diana Iwahashi, Hitoshi PeerJ Biochemistry The hybrid method upon combining rolling circle amplification and loop-mediated isothermal amplification (RCA-LAMP) was developed to quantify very small amount of different type of RNAs, such as miRNAs. RCA-LAMP can help detect short sequences through padlock probe (PLP) circularization and exhibit powerful DNA amplification. However, one of the factors that determines the detection limit of RCA-LAMP is non-specific amplification. In this study, we improved the accuracy of RCA-LAMP through applying RNase H-dependent PCR (rhPCR) technology. In this method, the non-specific amplification was suppressed by using the rh primer, which is designed through blocking the modification at the 3′end to stop DNA polymerase reaction and replacing the 6th DNA molecule from the end with RNA using RNase H2 enzyme. Traditional RCA-LAMP amplified the non-specific amplicons from linear PLP without a targeting reaction, while RCA-LAMP with rh primer and RNase H2 suppressed the non-specific amplification. Conversely, we identified the risk posed upon conducting PLP cyclization reaction using Splint R ligase in the RNA-targeting step that occurred even in the RNA-negative condition, which is another factor determining the detection limit of RCA-LAMP. Therefore, this study contributes in improving the accuracy of RNA quantification using RCA-LAMP. PeerJ Inc. 2021-07-30 /pmc/articles/PMC8327969/ /pubmed/34395086 http://dx.doi.org/10.7717/peerj.11851 Text en ©2021 Hasegawa et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, reproduction and adaptation in any medium and for any purpose provided that it is properly attributed. For attribution, the original author(s), title, publication source (PeerJ) and either DOI or URL of the article must be cited. |
spellingShingle | Biochemistry Hasegawa, Takema Hapsari, Diana Iwahashi, Hitoshi RNase H-dependent amplification improves the accuracy of rolling circle amplification combined with loop-mediated isothermal amplification (RCA-LAMP) |
title | RNase H-dependent amplification improves the accuracy of rolling circle amplification combined with loop-mediated isothermal amplification (RCA-LAMP) |
title_full | RNase H-dependent amplification improves the accuracy of rolling circle amplification combined with loop-mediated isothermal amplification (RCA-LAMP) |
title_fullStr | RNase H-dependent amplification improves the accuracy of rolling circle amplification combined with loop-mediated isothermal amplification (RCA-LAMP) |
title_full_unstemmed | RNase H-dependent amplification improves the accuracy of rolling circle amplification combined with loop-mediated isothermal amplification (RCA-LAMP) |
title_short | RNase H-dependent amplification improves the accuracy of rolling circle amplification combined with loop-mediated isothermal amplification (RCA-LAMP) |
title_sort | rnase h-dependent amplification improves the accuracy of rolling circle amplification combined with loop-mediated isothermal amplification (rca-lamp) |
topic | Biochemistry |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8327969/ https://www.ncbi.nlm.nih.gov/pubmed/34395086 http://dx.doi.org/10.7717/peerj.11851 |
work_keys_str_mv | AT hasegawatakema rnasehdependentamplificationimprovestheaccuracyofrollingcircleamplificationcombinedwithloopmediatedisothermalamplificationrcalamp AT hapsaridiana rnasehdependentamplificationimprovestheaccuracyofrollingcircleamplificationcombinedwithloopmediatedisothermalamplificationrcalamp AT iwahashihitoshi rnasehdependentamplificationimprovestheaccuracyofrollingcircleamplificationcombinedwithloopmediatedisothermalamplificationrcalamp |