Characterization of a PCB Based Pressure Sensor and Its Joining Methods for the Metal Membrane

Essential quality features of pressure sensors are, among other accuracy-related factors, measurement range, operating temperature, and long-term stability. In this work, these features are optimized for a capacitive pressure sensor with a measurement range of 10 bars. The sensor consists of a metal...

Descripción completa

Detalles Bibliográficos
Autores principales: Schwenck, Adrian, Grözinger, Tobias, Günther, Thomas, Schumacher, Axel, Schuhmacher, Dietmar, Werum, Kai, Zimmermann, André
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8402279/
https://www.ncbi.nlm.nih.gov/pubmed/34450995
http://dx.doi.org/10.3390/s21165557
_version_ 1783745751791173632
author Schwenck, Adrian
Grözinger, Tobias
Günther, Thomas
Schumacher, Axel
Schuhmacher, Dietmar
Werum, Kai
Zimmermann, André
author_facet Schwenck, Adrian
Grözinger, Tobias
Günther, Thomas
Schumacher, Axel
Schuhmacher, Dietmar
Werum, Kai
Zimmermann, André
author_sort Schwenck, Adrian
collection PubMed
description Essential quality features of pressure sensors are, among other accuracy-related factors, measurement range, operating temperature, and long-term stability. In this work, these features are optimized for a capacitive pressure sensor with a measurement range of 10 bars. The sensor consists of a metal membrane, which is connected to a PCB and a digital capacitive readout. To optimize the performance, different methods for the joining process are studied. Transient liquid phase bonding (TLP bonding), reactive joining, silver sintering, and electric resistance welding are compared by measurements of the characteristic curves and long-term measurements at maximum pressure. A scanning electron microscope (SEM) with energy-dispersive X-ray spectroscopy (EDX) analysis was used to examine the quality of the joints. The evaluation of the characteristic curves shows the smallest measurement errors for TLP bonding and sintering. For welding and sintering, no statistically significant long-term drift was measured. In terms of equipment costs, reactive joining and sintering are most favorable. With low material costs and short process times, electric resistance welding offers ideal conditions for mass production.
format Online
Article
Text
id pubmed-8402279
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-84022792021-08-29 Characterization of a PCB Based Pressure Sensor and Its Joining Methods for the Metal Membrane Schwenck, Adrian Grözinger, Tobias Günther, Thomas Schumacher, Axel Schuhmacher, Dietmar Werum, Kai Zimmermann, André Sensors (Basel) Article Essential quality features of pressure sensors are, among other accuracy-related factors, measurement range, operating temperature, and long-term stability. In this work, these features are optimized for a capacitive pressure sensor with a measurement range of 10 bars. The sensor consists of a metal membrane, which is connected to a PCB and a digital capacitive readout. To optimize the performance, different methods for the joining process are studied. Transient liquid phase bonding (TLP bonding), reactive joining, silver sintering, and electric resistance welding are compared by measurements of the characteristic curves and long-term measurements at maximum pressure. A scanning electron microscope (SEM) with energy-dispersive X-ray spectroscopy (EDX) analysis was used to examine the quality of the joints. The evaluation of the characteristic curves shows the smallest measurement errors for TLP bonding and sintering. For welding and sintering, no statistically significant long-term drift was measured. In terms of equipment costs, reactive joining and sintering are most favorable. With low material costs and short process times, electric resistance welding offers ideal conditions for mass production. MDPI 2021-08-18 /pmc/articles/PMC8402279/ /pubmed/34450995 http://dx.doi.org/10.3390/s21165557 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Schwenck, Adrian
Grözinger, Tobias
Günther, Thomas
Schumacher, Axel
Schuhmacher, Dietmar
Werum, Kai
Zimmermann, André
Characterization of a PCB Based Pressure Sensor and Its Joining Methods for the Metal Membrane
title Characterization of a PCB Based Pressure Sensor and Its Joining Methods for the Metal Membrane
title_full Characterization of a PCB Based Pressure Sensor and Its Joining Methods for the Metal Membrane
title_fullStr Characterization of a PCB Based Pressure Sensor and Its Joining Methods for the Metal Membrane
title_full_unstemmed Characterization of a PCB Based Pressure Sensor and Its Joining Methods for the Metal Membrane
title_short Characterization of a PCB Based Pressure Sensor and Its Joining Methods for the Metal Membrane
title_sort characterization of a pcb based pressure sensor and its joining methods for the metal membrane
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8402279/
https://www.ncbi.nlm.nih.gov/pubmed/34450995
http://dx.doi.org/10.3390/s21165557
work_keys_str_mv AT schwenckadrian characterizationofapcbbasedpressuresensoranditsjoiningmethodsforthemetalmembrane
AT grozingertobias characterizationofapcbbasedpressuresensoranditsjoiningmethodsforthemetalmembrane
AT guntherthomas characterizationofapcbbasedpressuresensoranditsjoiningmethodsforthemetalmembrane
AT schumacheraxel characterizationofapcbbasedpressuresensoranditsjoiningmethodsforthemetalmembrane
AT schuhmacherdietmar characterizationofapcbbasedpressuresensoranditsjoiningmethodsforthemetalmembrane
AT werumkai characterizationofapcbbasedpressuresensoranditsjoiningmethodsforthemetalmembrane
AT zimmermannandre characterizationofapcbbasedpressuresensoranditsjoiningmethodsforthemetalmembrane