Cargando…

Optimizing oxytocin LC-MS/MS sensitivity by choosing the right column

OBJECTIVE: Sensitivity is often an issue in bioanalytical LC-MS/MS applications. Commonly investigated parameters to improve it include additives to mobile phase, derivatization and sample-preparation. The nature of the column, however, is not frequently evaluated. DESIGN AND METHODS: The sensitivit...

Descripción completa

Detalles Bibliográficos
Autor principal: Ackermans, Mariëtte T.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8430380/
https://www.ncbi.nlm.nih.gov/pubmed/34527802
http://dx.doi.org/10.1016/j.plabm.2021.e00254
_version_ 1783750695433797632
author Ackermans, Mariëtte T.
author_facet Ackermans, Mariëtte T.
author_sort Ackermans, Mariëtte T.
collection PubMed
description OBJECTIVE: Sensitivity is often an issue in bioanalytical LC-MS/MS applications. Commonly investigated parameters to improve it include additives to mobile phase, derivatization and sample-preparation. The nature of the column, however, is not frequently evaluated. DESIGN AND METHODS: The sensitivity is compared for 18 different reversed phase and 2 different HILIC columns using 2 different mobile phase compositions. Sensitivity was evaluated in terms of S/N for 1,5 pg oxytocin on column, using a scouting gradient. RESULTS: The measured signal to noise ranged from 55 to 1473, indicating a substantial difference in sensitivity. The most sensitive columns were the Synergi Hydro RP (reversed phase) and the Atlantis HILIC (HILIC). CONCLUSIONS: This study shows that choosing the right column contributes to the sensitivity of the method.
format Online
Article
Text
id pubmed-8430380
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-84303802021-09-14 Optimizing oxytocin LC-MS/MS sensitivity by choosing the right column Ackermans, Mariëtte T. Pract Lab Med Article OBJECTIVE: Sensitivity is often an issue in bioanalytical LC-MS/MS applications. Commonly investigated parameters to improve it include additives to mobile phase, derivatization and sample-preparation. The nature of the column, however, is not frequently evaluated. DESIGN AND METHODS: The sensitivity is compared for 18 different reversed phase and 2 different HILIC columns using 2 different mobile phase compositions. Sensitivity was evaluated in terms of S/N for 1,5 pg oxytocin on column, using a scouting gradient. RESULTS: The measured signal to noise ranged from 55 to 1473, indicating a substantial difference in sensitivity. The most sensitive columns were the Synergi Hydro RP (reversed phase) and the Atlantis HILIC (HILIC). CONCLUSIONS: This study shows that choosing the right column contributes to the sensitivity of the method. Elsevier 2021-09-01 /pmc/articles/PMC8430380/ /pubmed/34527802 http://dx.doi.org/10.1016/j.plabm.2021.e00254 Text en © 2021 The Author https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ackermans, Mariëtte T.
Optimizing oxytocin LC-MS/MS sensitivity by choosing the right column
title Optimizing oxytocin LC-MS/MS sensitivity by choosing the right column
title_full Optimizing oxytocin LC-MS/MS sensitivity by choosing the right column
title_fullStr Optimizing oxytocin LC-MS/MS sensitivity by choosing the right column
title_full_unstemmed Optimizing oxytocin LC-MS/MS sensitivity by choosing the right column
title_short Optimizing oxytocin LC-MS/MS sensitivity by choosing the right column
title_sort optimizing oxytocin lc-ms/ms sensitivity by choosing the right column
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8430380/
https://www.ncbi.nlm.nih.gov/pubmed/34527802
http://dx.doi.org/10.1016/j.plabm.2021.e00254
work_keys_str_mv AT ackermansmariettet optimizingoxytocinlcmsmssensitivitybychoosingtherightcolumn