Hydromediastinum and hydrothorax as delayed complications of peripherally inserted central catheter used for total parenteral nutrition: A case report

INTRODUCTION: Central venous catheters (CVCs) and peripherally inserted central catheters (PICCs) may cause delayed complications, such as venous erosion, hydrothorax, or hydromediastinum. Vascular erosion is most frequently associated with left-sided CVC insertions. We report a case of hydropneumom...