Cargando…

Recognition of high-specificity hERG K+ channel inhibitor-induced arrhythmia in cardiomyocytes by automated template matching

Cardiovascular disease (CVD) is the number one cause of death in humans. Arrhythmia induced by gene mutations, heart disease, or hERG K(+) channel inhibitors is a serious CVD that can lead to sudden death or heart failure. Conventional cardiomyocyte-based biosensors can record extracellular potentia...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Hao, Li, Hongbo, Wei, Xinwei, Zhang, Tao, Xiang, Yuting, Fang, Jiaru, Wu, Peiran, Xie, Xi, Wang, Ping, Hu, Ning
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8433465/
https://www.ncbi.nlm.nih.gov/pubmed/34567738
http://dx.doi.org/10.1038/s41378-021-00251-4
_version_ 1783751383709646848
author Wang, Hao
Li, Hongbo
Wei, Xinwei
Zhang, Tao
Xiang, Yuting
Fang, Jiaru
Wu, Peiran
Xie, Xi
Wang, Ping
Hu, Ning
author_facet Wang, Hao
Li, Hongbo
Wei, Xinwei
Zhang, Tao
Xiang, Yuting
Fang, Jiaru
Wu, Peiran
Xie, Xi
Wang, Ping
Hu, Ning
author_sort Wang, Hao
collection PubMed
description Cardiovascular disease (CVD) is the number one cause of death in humans. Arrhythmia induced by gene mutations, heart disease, or hERG K(+) channel inhibitors is a serious CVD that can lead to sudden death or heart failure. Conventional cardiomyocyte-based biosensors can record extracellular potentials and mechanical beating signals. However, parameter extraction and examination by the naked eye are the traditional methods for analyzing arrhythmic beats, and it is difficult to achieve automated and efficient arrhythmic recognition with these methods. In this work, we developed a unique automated template matching (ATM) cardiomyocyte beating model to achieve arrhythmic recognition at the single beat level with an interdigitated electrode impedance detection system. The ATM model was established based on a rhythmic template with a data length that was dynamically adjusted to match the data length of the target beat by spline interpolation. The performance of the ATM model under long-term astemizole, droperidol, and sertindole treatment at different doses was determined. The results indicated that the ATM model based on a random rhythmic template of a signal segment obtained after astemizole treatment presented a higher recognition accuracy (100% for astemizole treatment and 99.14% for droperidol and sertindole treatment) than the ATM model based on arrhythmic multitemplates. We believe this highly specific ATM method based on a cardiomyocyte beating model has the potential to be used for arrhythmia screening in the fields of cardiology and pharmacology.
format Online
Article
Text
id pubmed-8433465
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-84334652021-09-24 Recognition of high-specificity hERG K+ channel inhibitor-induced arrhythmia in cardiomyocytes by automated template matching Wang, Hao Li, Hongbo Wei, Xinwei Zhang, Tao Xiang, Yuting Fang, Jiaru Wu, Peiran Xie, Xi Wang, Ping Hu, Ning Microsyst Nanoeng Article Cardiovascular disease (CVD) is the number one cause of death in humans. Arrhythmia induced by gene mutations, heart disease, or hERG K(+) channel inhibitors is a serious CVD that can lead to sudden death or heart failure. Conventional cardiomyocyte-based biosensors can record extracellular potentials and mechanical beating signals. However, parameter extraction and examination by the naked eye are the traditional methods for analyzing arrhythmic beats, and it is difficult to achieve automated and efficient arrhythmic recognition with these methods. In this work, we developed a unique automated template matching (ATM) cardiomyocyte beating model to achieve arrhythmic recognition at the single beat level with an interdigitated electrode impedance detection system. The ATM model was established based on a rhythmic template with a data length that was dynamically adjusted to match the data length of the target beat by spline interpolation. The performance of the ATM model under long-term astemizole, droperidol, and sertindole treatment at different doses was determined. The results indicated that the ATM model based on a random rhythmic template of a signal segment obtained after astemizole treatment presented a higher recognition accuracy (100% for astemizole treatment and 99.14% for droperidol and sertindole treatment) than the ATM model based on arrhythmic multitemplates. We believe this highly specific ATM method based on a cardiomyocyte beating model has the potential to be used for arrhythmia screening in the fields of cardiology and pharmacology. Nature Publishing Group UK 2021-03-16 /pmc/articles/PMC8433465/ /pubmed/34567738 http://dx.doi.org/10.1038/s41378-021-00251-4 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Wang, Hao
Li, Hongbo
Wei, Xinwei
Zhang, Tao
Xiang, Yuting
Fang, Jiaru
Wu, Peiran
Xie, Xi
Wang, Ping
Hu, Ning
Recognition of high-specificity hERG K+ channel inhibitor-induced arrhythmia in cardiomyocytes by automated template matching
title Recognition of high-specificity hERG K+ channel inhibitor-induced arrhythmia in cardiomyocytes by automated template matching
title_full Recognition of high-specificity hERG K+ channel inhibitor-induced arrhythmia in cardiomyocytes by automated template matching
title_fullStr Recognition of high-specificity hERG K+ channel inhibitor-induced arrhythmia in cardiomyocytes by automated template matching
title_full_unstemmed Recognition of high-specificity hERG K+ channel inhibitor-induced arrhythmia in cardiomyocytes by automated template matching
title_short Recognition of high-specificity hERG K+ channel inhibitor-induced arrhythmia in cardiomyocytes by automated template matching
title_sort recognition of high-specificity herg k+ channel inhibitor-induced arrhythmia in cardiomyocytes by automated template matching
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8433465/
https://www.ncbi.nlm.nih.gov/pubmed/34567738
http://dx.doi.org/10.1038/s41378-021-00251-4
work_keys_str_mv AT wanghao recognitionofhighspecificityhergkchannelinhibitorinducedarrhythmiaincardiomyocytesbyautomatedtemplatematching
AT lihongbo recognitionofhighspecificityhergkchannelinhibitorinducedarrhythmiaincardiomyocytesbyautomatedtemplatematching
AT weixinwei recognitionofhighspecificityhergkchannelinhibitorinducedarrhythmiaincardiomyocytesbyautomatedtemplatematching
AT zhangtao recognitionofhighspecificityhergkchannelinhibitorinducedarrhythmiaincardiomyocytesbyautomatedtemplatematching
AT xiangyuting recognitionofhighspecificityhergkchannelinhibitorinducedarrhythmiaincardiomyocytesbyautomatedtemplatematching
AT fangjiaru recognitionofhighspecificityhergkchannelinhibitorinducedarrhythmiaincardiomyocytesbyautomatedtemplatematching
AT wupeiran recognitionofhighspecificityhergkchannelinhibitorinducedarrhythmiaincardiomyocytesbyautomatedtemplatematching
AT xiexi recognitionofhighspecificityhergkchannelinhibitorinducedarrhythmiaincardiomyocytesbyautomatedtemplatematching
AT wangping recognitionofhighspecificityhergkchannelinhibitorinducedarrhythmiaincardiomyocytesbyautomatedtemplatematching
AT huning recognitionofhighspecificityhergkchannelinhibitorinducedarrhythmiaincardiomyocytesbyautomatedtemplatematching