Cargando…
Late leaflet dehiscence in a bovine bioprosthesis-mimicked COVID-19 infection
Symptoms mimicking COVID-19 infection, pulmonary emboli, or septicemia delayed diagnosis of aortic bioprosthesis failure. A 71-year-old man was admitted emergently with shortness of breath, fever, cough, and chest pain. Echocardiography performed after 2 days showed diastolic regurgitation in an aor...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8461114/ https://www.ncbi.nlm.nih.gov/pubmed/34567558 http://dx.doi.org/10.1177/2050313X211048039 |