Case Report: Efficiency of Embolization Microcoils for the Repair of Brachiocephalic Vein Perforation During Hemodialysis Catheter Placement

Background: The cuff catheter is one of the most common routes of vascular access in hemodialysis patients, while severe complications can occur during cuff catheter placement, such as bleeding, hematoma, and artery or vein damage. During catheterization, brachiocephalic vein perforation associated...