In-House Algorithm for Reporting Discrepant HbA1c Result and Troubleshooting a Case of False Low HbA1c
We report an unusual case of a patient having low glycosylated hemoglobin (HbA1c) below the reportable range, despite having borderline fasting blood glucose. The patient had decreased erythrocytes count and elevated reticulocyte count, with no evidence of hemoglobinopathy. He reported taking multid...