Cargando…
In-House Algorithm for Reporting Discrepant HbA1c Result and Troubleshooting a Case of False Low HbA1c
We report an unusual case of a patient having low glycosylated hemoglobin (HbA1c) below the reportable range, despite having borderline fasting blood glucose. The patient had decreased erythrocytes count and elevated reticulocyte count, with no evidence of hemoglobinopathy. He reported taking multid...
Autores principales: | Pant, Vivek, Shrestha, Abha, Pyakurel, Devish, Gautam, Keyoor, Pradhan, Santosh |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Communications and Publications Division (CPD) of the IFCC
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8592636/ https://www.ncbi.nlm.nih.gov/pubmed/34819826 |
Ejemplares similares
-
Measurement of HbA(1c) and HbA(2) by Capillarys 2 Flex Piercing HbA(1c) programme for simultaneous management of diabetes and screening for thalassemia
por: Ke, Peifeng, et al.
Publicado: (2017) -
Breast tuberculosis, a rare entity
por: Shrestha, Abha, et al.
Publicado: (2019) -
Sino-orbital mucormycosis in COVID recovered patient
por: Pant, Vivek, et al.
Publicado: (2022) -
The Hemoglobin Wayne Variant and Association With Falsely Elevated HbA(1c)
por: Mulpuri, Neha, et al.
Publicado: (2023) -
HbA(1c): The lower the better?
por: Araki, Eiichi, et al.
Publicado: (2011)