Quantification of Degradation Products Formed during Heat Sterilization of Glucose Solutions by LC-MS/MS: Impact of Autoclaving Temperature and Duration on Degradation

Heat sterilization of glucose solutions can lead to the formation of various glucose degradation products (GDPs) due to oxidation, hydrolysis, and dehydration. GDPs can have toxic effects after parenteral administration due to their high reactivity. In this study, the application of the F0 concept t...

Descripción completa

Detalles Bibliográficos
Autores principales: Leitzen, Sarah, Vogel, Matthias, Steffens, Michael, Zapf, Thomas, Müller, Christa Elisabeth, Brandl, Martin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8625795/
https://www.ncbi.nlm.nih.gov/pubmed/34832903
http://dx.doi.org/10.3390/ph14111121
_version_ 1784606509067403264
author Leitzen, Sarah
Vogel, Matthias
Steffens, Michael
Zapf, Thomas
Müller, Christa Elisabeth
Brandl, Martin
author_facet Leitzen, Sarah
Vogel, Matthias
Steffens, Michael
Zapf, Thomas
Müller, Christa Elisabeth
Brandl, Martin
author_sort Leitzen, Sarah
collection PubMed
description Heat sterilization of glucose solutions can lead to the formation of various glucose degradation products (GDPs) due to oxidation, hydrolysis, and dehydration. GDPs can have toxic effects after parenteral administration due to their high reactivity. In this study, the application of the F0 concept to modify specific time/temperature models during heat sterilization and their influence on the formation of GDPs in parenteral glucose solutions was investigated using high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). Glucose solutions (10%, w/v) were autoclaved at 111 °C, 116 °C, and 121 °C for different durations. The GDPs glyoxal, methylglyoxal, glucosone, 3-deoxyglucosone/3-deoxygalactosone, 3,4-dideoxyglucosone-3-ene, and 5-hydroxymethylfurfural were quantified after derivatization with o-phenylenediamine by an optimized LC-MS/MS method. For all GDPs, the limit of detection was <0.078 μg/mL, and the limit of quantification was <0.236 μg/mL. The autoclaving time of 121 °C and 15 min resulted in the lowest levels of 3-DG/3-DGal and 5-HMF, but in the highest levels of GO and 2-KDG. The proposed LC-MS/MS method is rapid and sensitive. So far, only 5-HMF concentrations are limited by the regulatory authorities. Our results suggest reconsidering the impurity limits of various GDPs, especially the more toxic ones such as GO and MGO, by the Pharmacopoeias.
format Online
Article
Text
id pubmed-8625795
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-86257952021-11-27 Quantification of Degradation Products Formed during Heat Sterilization of Glucose Solutions by LC-MS/MS: Impact of Autoclaving Temperature and Duration on Degradation Leitzen, Sarah Vogel, Matthias Steffens, Michael Zapf, Thomas Müller, Christa Elisabeth Brandl, Martin Pharmaceuticals (Basel) Article Heat sterilization of glucose solutions can lead to the formation of various glucose degradation products (GDPs) due to oxidation, hydrolysis, and dehydration. GDPs can have toxic effects after parenteral administration due to their high reactivity. In this study, the application of the F0 concept to modify specific time/temperature models during heat sterilization and their influence on the formation of GDPs in parenteral glucose solutions was investigated using high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). Glucose solutions (10%, w/v) were autoclaved at 111 °C, 116 °C, and 121 °C for different durations. The GDPs glyoxal, methylglyoxal, glucosone, 3-deoxyglucosone/3-deoxygalactosone, 3,4-dideoxyglucosone-3-ene, and 5-hydroxymethylfurfural were quantified after derivatization with o-phenylenediamine by an optimized LC-MS/MS method. For all GDPs, the limit of detection was <0.078 μg/mL, and the limit of quantification was <0.236 μg/mL. The autoclaving time of 121 °C and 15 min resulted in the lowest levels of 3-DG/3-DGal and 5-HMF, but in the highest levels of GO and 2-KDG. The proposed LC-MS/MS method is rapid and sensitive. So far, only 5-HMF concentrations are limited by the regulatory authorities. Our results suggest reconsidering the impurity limits of various GDPs, especially the more toxic ones such as GO and MGO, by the Pharmacopoeias. MDPI 2021-11-01 /pmc/articles/PMC8625795/ /pubmed/34832903 http://dx.doi.org/10.3390/ph14111121 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Leitzen, Sarah
Vogel, Matthias
Steffens, Michael
Zapf, Thomas
Müller, Christa Elisabeth
Brandl, Martin
Quantification of Degradation Products Formed during Heat Sterilization of Glucose Solutions by LC-MS/MS: Impact of Autoclaving Temperature and Duration on Degradation
title Quantification of Degradation Products Formed during Heat Sterilization of Glucose Solutions by LC-MS/MS: Impact of Autoclaving Temperature and Duration on Degradation
title_full Quantification of Degradation Products Formed during Heat Sterilization of Glucose Solutions by LC-MS/MS: Impact of Autoclaving Temperature and Duration on Degradation
title_fullStr Quantification of Degradation Products Formed during Heat Sterilization of Glucose Solutions by LC-MS/MS: Impact of Autoclaving Temperature and Duration on Degradation
title_full_unstemmed Quantification of Degradation Products Formed during Heat Sterilization of Glucose Solutions by LC-MS/MS: Impact of Autoclaving Temperature and Duration on Degradation
title_short Quantification of Degradation Products Formed during Heat Sterilization of Glucose Solutions by LC-MS/MS: Impact of Autoclaving Temperature and Duration on Degradation
title_sort quantification of degradation products formed during heat sterilization of glucose solutions by lc-ms/ms: impact of autoclaving temperature and duration on degradation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8625795/
https://www.ncbi.nlm.nih.gov/pubmed/34832903
http://dx.doi.org/10.3390/ph14111121
work_keys_str_mv AT leitzensarah quantificationofdegradationproductsformedduringheatsterilizationofglucosesolutionsbylcmsmsimpactofautoclavingtemperatureanddurationondegradation
AT vogelmatthias quantificationofdegradationproductsformedduringheatsterilizationofglucosesolutionsbylcmsmsimpactofautoclavingtemperatureanddurationondegradation
AT steffensmichael quantificationofdegradationproductsformedduringheatsterilizationofglucosesolutionsbylcmsmsimpactofautoclavingtemperatureanddurationondegradation
AT zapfthomas quantificationofdegradationproductsformedduringheatsterilizationofglucosesolutionsbylcmsmsimpactofautoclavingtemperatureanddurationondegradation
AT mullerchristaelisabeth quantificationofdegradationproductsformedduringheatsterilizationofglucosesolutionsbylcmsmsimpactofautoclavingtemperatureanddurationondegradation
AT brandlmartin quantificationofdegradationproductsformedduringheatsterilizationofglucosesolutionsbylcmsmsimpactofautoclavingtemperatureanddurationondegradation