Quantification of Degradation Products Formed during Heat Sterilization of Glucose Solutions by LC-MS/MS: Impact of Autoclaving Temperature and Duration on Degradation
Heat sterilization of glucose solutions can lead to the formation of various glucose degradation products (GDPs) due to oxidation, hydrolysis, and dehydration. GDPs can have toxic effects after parenteral administration due to their high reactivity. In this study, the application of the F0 concept t...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8625795/ https://www.ncbi.nlm.nih.gov/pubmed/34832903 http://dx.doi.org/10.3390/ph14111121 |
_version_ | 1784606509067403264 |
---|---|
author | Leitzen, Sarah Vogel, Matthias Steffens, Michael Zapf, Thomas Müller, Christa Elisabeth Brandl, Martin |
author_facet | Leitzen, Sarah Vogel, Matthias Steffens, Michael Zapf, Thomas Müller, Christa Elisabeth Brandl, Martin |
author_sort | Leitzen, Sarah |
collection | PubMed |
description | Heat sterilization of glucose solutions can lead to the formation of various glucose degradation products (GDPs) due to oxidation, hydrolysis, and dehydration. GDPs can have toxic effects after parenteral administration due to their high reactivity. In this study, the application of the F0 concept to modify specific time/temperature models during heat sterilization and their influence on the formation of GDPs in parenteral glucose solutions was investigated using high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). Glucose solutions (10%, w/v) were autoclaved at 111 °C, 116 °C, and 121 °C for different durations. The GDPs glyoxal, methylglyoxal, glucosone, 3-deoxyglucosone/3-deoxygalactosone, 3,4-dideoxyglucosone-3-ene, and 5-hydroxymethylfurfural were quantified after derivatization with o-phenylenediamine by an optimized LC-MS/MS method. For all GDPs, the limit of detection was <0.078 μg/mL, and the limit of quantification was <0.236 μg/mL. The autoclaving time of 121 °C and 15 min resulted in the lowest levels of 3-DG/3-DGal and 5-HMF, but in the highest levels of GO and 2-KDG. The proposed LC-MS/MS method is rapid and sensitive. So far, only 5-HMF concentrations are limited by the regulatory authorities. Our results suggest reconsidering the impurity limits of various GDPs, especially the more toxic ones such as GO and MGO, by the Pharmacopoeias. |
format | Online Article Text |
id | pubmed-8625795 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-86257952021-11-27 Quantification of Degradation Products Formed during Heat Sterilization of Glucose Solutions by LC-MS/MS: Impact of Autoclaving Temperature and Duration on Degradation Leitzen, Sarah Vogel, Matthias Steffens, Michael Zapf, Thomas Müller, Christa Elisabeth Brandl, Martin Pharmaceuticals (Basel) Article Heat sterilization of glucose solutions can lead to the formation of various glucose degradation products (GDPs) due to oxidation, hydrolysis, and dehydration. GDPs can have toxic effects after parenteral administration due to their high reactivity. In this study, the application of the F0 concept to modify specific time/temperature models during heat sterilization and their influence on the formation of GDPs in parenteral glucose solutions was investigated using high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). Glucose solutions (10%, w/v) were autoclaved at 111 °C, 116 °C, and 121 °C for different durations. The GDPs glyoxal, methylglyoxal, glucosone, 3-deoxyglucosone/3-deoxygalactosone, 3,4-dideoxyglucosone-3-ene, and 5-hydroxymethylfurfural were quantified after derivatization with o-phenylenediamine by an optimized LC-MS/MS method. For all GDPs, the limit of detection was <0.078 μg/mL, and the limit of quantification was <0.236 μg/mL. The autoclaving time of 121 °C and 15 min resulted in the lowest levels of 3-DG/3-DGal and 5-HMF, but in the highest levels of GO and 2-KDG. The proposed LC-MS/MS method is rapid and sensitive. So far, only 5-HMF concentrations are limited by the regulatory authorities. Our results suggest reconsidering the impurity limits of various GDPs, especially the more toxic ones such as GO and MGO, by the Pharmacopoeias. MDPI 2021-11-01 /pmc/articles/PMC8625795/ /pubmed/34832903 http://dx.doi.org/10.3390/ph14111121 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Leitzen, Sarah Vogel, Matthias Steffens, Michael Zapf, Thomas Müller, Christa Elisabeth Brandl, Martin Quantification of Degradation Products Formed during Heat Sterilization of Glucose Solutions by LC-MS/MS: Impact of Autoclaving Temperature and Duration on Degradation |
title | Quantification of Degradation Products Formed during Heat Sterilization of Glucose Solutions by LC-MS/MS: Impact of Autoclaving Temperature and Duration on Degradation |
title_full | Quantification of Degradation Products Formed during Heat Sterilization of Glucose Solutions by LC-MS/MS: Impact of Autoclaving Temperature and Duration on Degradation |
title_fullStr | Quantification of Degradation Products Formed during Heat Sterilization of Glucose Solutions by LC-MS/MS: Impact of Autoclaving Temperature and Duration on Degradation |
title_full_unstemmed | Quantification of Degradation Products Formed during Heat Sterilization of Glucose Solutions by LC-MS/MS: Impact of Autoclaving Temperature and Duration on Degradation |
title_short | Quantification of Degradation Products Formed during Heat Sterilization of Glucose Solutions by LC-MS/MS: Impact of Autoclaving Temperature and Duration on Degradation |
title_sort | quantification of degradation products formed during heat sterilization of glucose solutions by lc-ms/ms: impact of autoclaving temperature and duration on degradation |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8625795/ https://www.ncbi.nlm.nih.gov/pubmed/34832903 http://dx.doi.org/10.3390/ph14111121 |
work_keys_str_mv | AT leitzensarah quantificationofdegradationproductsformedduringheatsterilizationofglucosesolutionsbylcmsmsimpactofautoclavingtemperatureanddurationondegradation AT vogelmatthias quantificationofdegradationproductsformedduringheatsterilizationofglucosesolutionsbylcmsmsimpactofautoclavingtemperatureanddurationondegradation AT steffensmichael quantificationofdegradationproductsformedduringheatsterilizationofglucosesolutionsbylcmsmsimpactofautoclavingtemperatureanddurationondegradation AT zapfthomas quantificationofdegradationproductsformedduringheatsterilizationofglucosesolutionsbylcmsmsimpactofautoclavingtemperatureanddurationondegradation AT mullerchristaelisabeth quantificationofdegradationproductsformedduringheatsterilizationofglucosesolutionsbylcmsmsimpactofautoclavingtemperatureanddurationondegradation AT brandlmartin quantificationofdegradationproductsformedduringheatsterilizationofglucosesolutionsbylcmsmsimpactofautoclavingtemperatureanddurationondegradation |