Cargando…

CFNet: LiDAR-Camera Registration Using Calibration Flow Network

As an essential procedure of data fusion, LiDAR-camera calibration is critical for autonomous vehicles and robot navigation. Most calibration methods require laborious manual work, complicated environmental settings, and specific calibration targets. The targetless methods are based on some complex...

Descripción completa

Detalles Bibliográficos
Autores principales: Lv, Xudong, Wang, Shuo, Ye, Dong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8662422/
https://www.ncbi.nlm.nih.gov/pubmed/34884116
http://dx.doi.org/10.3390/s21238112
_version_ 1784613432421515264
author Lv, Xudong
Wang, Shuo
Ye, Dong
author_facet Lv, Xudong
Wang, Shuo
Ye, Dong
author_sort Lv, Xudong
collection PubMed
description As an essential procedure of data fusion, LiDAR-camera calibration is critical for autonomous vehicles and robot navigation. Most calibration methods require laborious manual work, complicated environmental settings, and specific calibration targets. The targetless methods are based on some complex optimization workflow, which is time-consuming and requires prior information. Convolutional neural networks (CNNs) can regress the six degrees of freedom (6-DOF) extrinsic parameters from raw LiDAR and image data. However, these CNN-based methods just learn the representations of the projected LiDAR and image and ignore the correspondences at different locations. The performances of these CNN-based methods are unsatisfactory and worse than those of non-CNN methods. In this paper, we propose a novel CNN-based LiDAR-camera extrinsic calibration algorithm named CFNet. We first decided that a correlation layer should be used to provide matching capabilities explicitly. Then, we innovatively defined calibration flow to illustrate the deviation of the initial projection from the ground truth. Instead of directly predicting the extrinsic parameters, we utilize CFNet to predict the calibration flow. The efficient Perspective-n-Point (EPnP) algorithm within the RANdom SAmple Consensus (RANSAC) scheme is applied to estimate the extrinsic parameters with 2D–3D correspondences constructed by the calibration flow. Due to its consideration of the geometric information, our proposed method performed better than the state-of-the-art CNN-based methods on the KITTI datasets. Furthermore, we also tested the flexibility of our approach on the KITTI360 datasets.
format Online
Article
Text
id pubmed-8662422
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-86624222021-12-11 CFNet: LiDAR-Camera Registration Using Calibration Flow Network Lv, Xudong Wang, Shuo Ye, Dong Sensors (Basel) Article As an essential procedure of data fusion, LiDAR-camera calibration is critical for autonomous vehicles and robot navigation. Most calibration methods require laborious manual work, complicated environmental settings, and specific calibration targets. The targetless methods are based on some complex optimization workflow, which is time-consuming and requires prior information. Convolutional neural networks (CNNs) can regress the six degrees of freedom (6-DOF) extrinsic parameters from raw LiDAR and image data. However, these CNN-based methods just learn the representations of the projected LiDAR and image and ignore the correspondences at different locations. The performances of these CNN-based methods are unsatisfactory and worse than those of non-CNN methods. In this paper, we propose a novel CNN-based LiDAR-camera extrinsic calibration algorithm named CFNet. We first decided that a correlation layer should be used to provide matching capabilities explicitly. Then, we innovatively defined calibration flow to illustrate the deviation of the initial projection from the ground truth. Instead of directly predicting the extrinsic parameters, we utilize CFNet to predict the calibration flow. The efficient Perspective-n-Point (EPnP) algorithm within the RANdom SAmple Consensus (RANSAC) scheme is applied to estimate the extrinsic parameters with 2D–3D correspondences constructed by the calibration flow. Due to its consideration of the geometric information, our proposed method performed better than the state-of-the-art CNN-based methods on the KITTI datasets. Furthermore, we also tested the flexibility of our approach on the KITTI360 datasets. MDPI 2021-12-04 /pmc/articles/PMC8662422/ /pubmed/34884116 http://dx.doi.org/10.3390/s21238112 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lv, Xudong
Wang, Shuo
Ye, Dong
CFNet: LiDAR-Camera Registration Using Calibration Flow Network
title CFNet: LiDAR-Camera Registration Using Calibration Flow Network
title_full CFNet: LiDAR-Camera Registration Using Calibration Flow Network
title_fullStr CFNet: LiDAR-Camera Registration Using Calibration Flow Network
title_full_unstemmed CFNet: LiDAR-Camera Registration Using Calibration Flow Network
title_short CFNet: LiDAR-Camera Registration Using Calibration Flow Network
title_sort cfnet: lidar-camera registration using calibration flow network
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8662422/
https://www.ncbi.nlm.nih.gov/pubmed/34884116
http://dx.doi.org/10.3390/s21238112
work_keys_str_mv AT lvxudong cfnetlidarcameraregistrationusingcalibrationflownetwork
AT wangshuo cfnetlidarcameraregistrationusingcalibrationflownetwork
AT yedong cfnetlidarcameraregistrationusingcalibrationflownetwork