Cargando…

Evaluation of the Effect of Different Types of Fluoride on Tensile Properties and Surface Roughness of Different Titanium-Based Archwires: An In vivo Study

OBJECTIVES: The purpose of the study was to evaluate the effect of different types of fluoride on tensile properties and surface roughness of titanium based archwires clinically. MATERIALS AND METHODS: Three groups of archwires, namely nickel–titanium (NiTi), heat activated NiTi, and TMA was evaluat...

Descripción completa

Detalles Bibliográficos
Autores principales: Balakrishnan, Rajkumar, Jeri, Sumaya Yousuf, Rekha, V. R., Singh, Gangesh Bahadur, Deepak, P. R., Nair, Achuthan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8686913/
https://www.ncbi.nlm.nih.gov/pubmed/35017955
http://dx.doi.org/10.4103/jpbs.jpbs_341_21