Cargando…

Myoelectric control of robotic lower limb prostheses: a review of electromyography interfaces, control paradigms, challenges and future directions

OBJECTIVE. Advanced robotic lower limb prostheses are mainly controlled autonomously. Although the existing control can assist cyclic movements during locomotion of amputee users, the function of these modern devices is still limited due to the lack of neuromuscular control (i.e. control based on hu...

Descripción completa

Detalles Bibliográficos
Autores principales: Fleming, Aaron, Stafford, Nicole, Huang, Stephanie, Hu, Xiaogang, Ferris, Daniel P, Huang, He (Helen)
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8694273/
https://www.ncbi.nlm.nih.gov/pubmed/34229307
http://dx.doi.org/10.1088/1741-2552/ac1176
_version_ 1784619317576335360
author Fleming, Aaron
Stafford, Nicole
Huang, Stephanie
Hu, Xiaogang
Ferris, Daniel P
Huang, He (Helen)
author_facet Fleming, Aaron
Stafford, Nicole
Huang, Stephanie
Hu, Xiaogang
Ferris, Daniel P
Huang, He (Helen)
author_sort Fleming, Aaron
collection PubMed
description OBJECTIVE. Advanced robotic lower limb prostheses are mainly controlled autonomously. Although the existing control can assist cyclic movements during locomotion of amputee users, the function of these modern devices is still limited due to the lack of neuromuscular control (i.e. control based on human efferent neural signals from the central nervous system to peripheral muscles for movement production). Neuromuscular control signals can be recorded from muscles, called electromyographic (EMG) or myoelectric signals. In fact, using EMG signals for robotic lower limb prostheses control has been an emerging research topic in the field for the past decade to address novel prosthesis functionality and adaptability to different environments and task contexts. The objective of this paper is to review robotic lower limb Prosthesis control via EMG signals recorded from residual muscles in individuals with lower limb amputations. APPROACH. We performed a literature review on surgical techniques for enhanced EMG interfaces, EMG sensors, decoding algorithms, and control paradigms for robotic lower limb prostheses. MAIN RESULTS. This review highlights the promise of EMG control for enabling new functionalities in robotic lower limb prostheses, as well as the existing challenges, knowledge gaps, and opportunities on this research topic from human motor control and clinical practice perspectives. SIGNIFICANCE. This review may guide the future collaborations among researchers in neuromechanics, neural engineering, assistive technologies, and amputee clinics in order to build and translate true bionic lower limbs to individuals with lower limb amputations for improved motor function.
format Online
Article
Text
id pubmed-8694273
institution National Center for Biotechnology Information
language English
publishDate 2021
record_format MEDLINE/PubMed
spelling pubmed-86942732021-12-22 Myoelectric control of robotic lower limb prostheses: a review of electromyography interfaces, control paradigms, challenges and future directions Fleming, Aaron Stafford, Nicole Huang, Stephanie Hu, Xiaogang Ferris, Daniel P Huang, He (Helen) J Neural Eng Article OBJECTIVE. Advanced robotic lower limb prostheses are mainly controlled autonomously. Although the existing control can assist cyclic movements during locomotion of amputee users, the function of these modern devices is still limited due to the lack of neuromuscular control (i.e. control based on human efferent neural signals from the central nervous system to peripheral muscles for movement production). Neuromuscular control signals can be recorded from muscles, called electromyographic (EMG) or myoelectric signals. In fact, using EMG signals for robotic lower limb prostheses control has been an emerging research topic in the field for the past decade to address novel prosthesis functionality and adaptability to different environments and task contexts. The objective of this paper is to review robotic lower limb Prosthesis control via EMG signals recorded from residual muscles in individuals with lower limb amputations. APPROACH. We performed a literature review on surgical techniques for enhanced EMG interfaces, EMG sensors, decoding algorithms, and control paradigms for robotic lower limb prostheses. MAIN RESULTS. This review highlights the promise of EMG control for enabling new functionalities in robotic lower limb prostheses, as well as the existing challenges, knowledge gaps, and opportunities on this research topic from human motor control and clinical practice perspectives. SIGNIFICANCE. This review may guide the future collaborations among researchers in neuromechanics, neural engineering, assistive technologies, and amputee clinics in order to build and translate true bionic lower limbs to individuals with lower limb amputations for improved motor function. 2021-07-27 /pmc/articles/PMC8694273/ /pubmed/34229307 http://dx.doi.org/10.1088/1741-2552/ac1176 Text en https://creativecommons.org/licenses/by/4.0/Original content from this work may be used under the terms of the Creative Commons Attribution 4.0 licence (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Fleming, Aaron
Stafford, Nicole
Huang, Stephanie
Hu, Xiaogang
Ferris, Daniel P
Huang, He (Helen)
Myoelectric control of robotic lower limb prostheses: a review of electromyography interfaces, control paradigms, challenges and future directions
title Myoelectric control of robotic lower limb prostheses: a review of electromyography interfaces, control paradigms, challenges and future directions
title_full Myoelectric control of robotic lower limb prostheses: a review of electromyography interfaces, control paradigms, challenges and future directions
title_fullStr Myoelectric control of robotic lower limb prostheses: a review of electromyography interfaces, control paradigms, challenges and future directions
title_full_unstemmed Myoelectric control of robotic lower limb prostheses: a review of electromyography interfaces, control paradigms, challenges and future directions
title_short Myoelectric control of robotic lower limb prostheses: a review of electromyography interfaces, control paradigms, challenges and future directions
title_sort myoelectric control of robotic lower limb prostheses: a review of electromyography interfaces, control paradigms, challenges and future directions
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8694273/
https://www.ncbi.nlm.nih.gov/pubmed/34229307
http://dx.doi.org/10.1088/1741-2552/ac1176
work_keys_str_mv AT flemingaaron myoelectriccontrolofroboticlowerlimbprosthesesareviewofelectromyographyinterfacescontrolparadigmschallengesandfuturedirections
AT staffordnicole myoelectriccontrolofroboticlowerlimbprosthesesareviewofelectromyographyinterfacescontrolparadigmschallengesandfuturedirections
AT huangstephanie myoelectriccontrolofroboticlowerlimbprosthesesareviewofelectromyographyinterfacescontrolparadigmschallengesandfuturedirections
AT huxiaogang myoelectriccontrolofroboticlowerlimbprosthesesareviewofelectromyographyinterfacescontrolparadigmschallengesandfuturedirections
AT ferrisdanielp myoelectriccontrolofroboticlowerlimbprosthesesareviewofelectromyographyinterfacescontrolparadigmschallengesandfuturedirections
AT huanghehelen myoelectriccontrolofroboticlowerlimbprosthesesareviewofelectromyographyinterfacescontrolparadigmschallengesandfuturedirections