Cargando…
Development and validation of a sensitive LC-MS/MS method for pioglitazone: application towards pharmacokinetic and tissue distribution study in rats
In the present study, a sensitive LC-MS/MS method was developed and validated to measure pioglitazone (PGZ) concentrations in rat plasma and tissues. The chromatographic separation was achieved by using a YMC Pro C(18) column (100 mm × 4.6 mm, 3μ) with a mobile phase consisting of formic acid (0.1%...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Royal Society of Chemistry
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8695949/ https://www.ncbi.nlm.nih.gov/pubmed/35423625 http://dx.doi.org/10.1039/d1ra01126j |
_version_ | 1784619695708569600 |
---|---|
author | G., Kusuma Kumari Thaggikuppe Krishnamurthy, Praveen Ammu V. V. V., Ravi Kiran Vishwanath, Kurawattimath Narenderan, S. T. Babu, B. Krishnaveni, Nagappan |
author_facet | G., Kusuma Kumari Thaggikuppe Krishnamurthy, Praveen Ammu V. V. V., Ravi Kiran Vishwanath, Kurawattimath Narenderan, S. T. Babu, B. Krishnaveni, Nagappan |
author_sort | G., Kusuma Kumari |
collection | PubMed |
description | In the present study, a sensitive LC-MS/MS method was developed and validated to measure pioglitazone (PGZ) concentrations in rat plasma and tissues. The chromatographic separation was achieved by using a YMC Pro C(18) column (100 mm × 4.6 mm, 3μ) with a mobile phase consisting of formic acid (0.1% v/v) and acetonitrile (5 : 95) at a flow rate of 0.7 mL min(−1) and injection volume of 10 μL (IS: rosiglitazone). Mass spectrometric detection was done using triple quadrupole mass spectrometry using the ESI interface operating in a positive ionization mode. The developed method was validated over a linearity range of 1–500 ng mL(−1) with detection and a lower quantification limit of 0.5 ng mL(−1) and 1 ng mL(−1). The method accuracy ranged from 95.89–98.78% (inter-day) & 93.39–97.68% (intra-day) with a precision range of 6.09–8.12% for inter-day & 7.55–9.87% for intra-day, respectively. The PGZ shows the highest C(max) of 495.03 ng mL(−1) in plasma and the lowest C(max), 24.50 ± 2.71 ng mL(−1) in bone. The maximum T(max) of 5.00 ± 0.49 h was observed in bone and a minimum of 1.01 ± 0.05 h in plasma. The AUC((0–24 h and 0–∞)) values are highest in plasma (1056.58 ± 65.78 & 1069.38 ± 77.50 ng h(−1) mL(−1)) and lowest in brain (166.93 ± 15.70 &167.12 ± 16.77 ng h(−1) mL(−1)), and the T(1/2) was highest in plasma (5.62 ± 0.74 h) and lowest in kidney (2.78 ± 0.19). The developed method was successfully used to measure the PGZ pharmacokinetic and tissue distribution. Further, the developed method could be utilized for validating target organ (adipose tissue) specific delivery of PGZ (nano-formulations) in addition to conventional dosage forms. |
format | Online Article Text |
id | pubmed-8695949 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | The Royal Society of Chemistry |
record_format | MEDLINE/PubMed |
spelling | pubmed-86959492022-04-13 Development and validation of a sensitive LC-MS/MS method for pioglitazone: application towards pharmacokinetic and tissue distribution study in rats G., Kusuma Kumari Thaggikuppe Krishnamurthy, Praveen Ammu V. V. V., Ravi Kiran Vishwanath, Kurawattimath Narenderan, S. T. Babu, B. Krishnaveni, Nagappan RSC Adv Chemistry In the present study, a sensitive LC-MS/MS method was developed and validated to measure pioglitazone (PGZ) concentrations in rat plasma and tissues. The chromatographic separation was achieved by using a YMC Pro C(18) column (100 mm × 4.6 mm, 3μ) with a mobile phase consisting of formic acid (0.1% v/v) and acetonitrile (5 : 95) at a flow rate of 0.7 mL min(−1) and injection volume of 10 μL (IS: rosiglitazone). Mass spectrometric detection was done using triple quadrupole mass spectrometry using the ESI interface operating in a positive ionization mode. The developed method was validated over a linearity range of 1–500 ng mL(−1) with detection and a lower quantification limit of 0.5 ng mL(−1) and 1 ng mL(−1). The method accuracy ranged from 95.89–98.78% (inter-day) & 93.39–97.68% (intra-day) with a precision range of 6.09–8.12% for inter-day & 7.55–9.87% for intra-day, respectively. The PGZ shows the highest C(max) of 495.03 ng mL(−1) in plasma and the lowest C(max), 24.50 ± 2.71 ng mL(−1) in bone. The maximum T(max) of 5.00 ± 0.49 h was observed in bone and a minimum of 1.01 ± 0.05 h in plasma. The AUC((0–24 h and 0–∞)) values are highest in plasma (1056.58 ± 65.78 & 1069.38 ± 77.50 ng h(−1) mL(−1)) and lowest in brain (166.93 ± 15.70 &167.12 ± 16.77 ng h(−1) mL(−1)), and the T(1/2) was highest in plasma (5.62 ± 0.74 h) and lowest in kidney (2.78 ± 0.19). The developed method was successfully used to measure the PGZ pharmacokinetic and tissue distribution. Further, the developed method could be utilized for validating target organ (adipose tissue) specific delivery of PGZ (nano-formulations) in addition to conventional dosage forms. The Royal Society of Chemistry 2021-03-18 /pmc/articles/PMC8695949/ /pubmed/35423625 http://dx.doi.org/10.1039/d1ra01126j Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by/3.0/ |
spellingShingle | Chemistry G., Kusuma Kumari Thaggikuppe Krishnamurthy, Praveen Ammu V. V. V., Ravi Kiran Vishwanath, Kurawattimath Narenderan, S. T. Babu, B. Krishnaveni, Nagappan Development and validation of a sensitive LC-MS/MS method for pioglitazone: application towards pharmacokinetic and tissue distribution study in rats |
title | Development and validation of a sensitive LC-MS/MS method for pioglitazone: application towards pharmacokinetic and tissue distribution study in rats |
title_full | Development and validation of a sensitive LC-MS/MS method for pioglitazone: application towards pharmacokinetic and tissue distribution study in rats |
title_fullStr | Development and validation of a sensitive LC-MS/MS method for pioglitazone: application towards pharmacokinetic and tissue distribution study in rats |
title_full_unstemmed | Development and validation of a sensitive LC-MS/MS method for pioglitazone: application towards pharmacokinetic and tissue distribution study in rats |
title_short | Development and validation of a sensitive LC-MS/MS method for pioglitazone: application towards pharmacokinetic and tissue distribution study in rats |
title_sort | development and validation of a sensitive lc-ms/ms method for pioglitazone: application towards pharmacokinetic and tissue distribution study in rats |
topic | Chemistry |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8695949/ https://www.ncbi.nlm.nih.gov/pubmed/35423625 http://dx.doi.org/10.1039/d1ra01126j |
work_keys_str_mv | AT gkusumakumari developmentandvalidationofasensitivelcmsmsmethodforpioglitazoneapplicationtowardspharmacokineticandtissuedistributionstudyinrats AT thaggikuppekrishnamurthypraveen developmentandvalidationofasensitivelcmsmsmethodforpioglitazoneapplicationtowardspharmacokineticandtissuedistributionstudyinrats AT ammuvvvravikiran developmentandvalidationofasensitivelcmsmsmethodforpioglitazoneapplicationtowardspharmacokineticandtissuedistributionstudyinrats AT vishwanathkurawattimath developmentandvalidationofasensitivelcmsmsmethodforpioglitazoneapplicationtowardspharmacokineticandtissuedistributionstudyinrats AT narenderanst developmentandvalidationofasensitivelcmsmsmethodforpioglitazoneapplicationtowardspharmacokineticandtissuedistributionstudyinrats AT babub developmentandvalidationofasensitivelcmsmsmethodforpioglitazoneapplicationtowardspharmacokineticandtissuedistributionstudyinrats AT krishnaveninagappan developmentandvalidationofasensitivelcmsmsmethodforpioglitazoneapplicationtowardspharmacokineticandtissuedistributionstudyinrats |