Fully Automated Quantitative Measurement of Serum Organic Acids via LC-MS/MS for the Diagnosis of Organic Acidemias: Establishment of an Automation System and a Proof-of-Concept Validation

Gas chromatography-mass spectrometry has been widely used to analyze hundreds of organic acids in urine to provide a diagnostic basis for organic acidemia. However, it is difficult to operate in clinical laboratories on a daily basis due to sample pretreatment processing. Therefore, we aimed to deve...

Descripción completa

Detalles Bibliográficos
Autores principales: Ueyanagi, Yasushi, Setoyama, Daiki, Kawakami, Daisuke, Mushimoto, Yuichi, Matsumoto, Shinya, Hotta, Taeko, Kang, Dongchon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8700112/
https://www.ncbi.nlm.nih.gov/pubmed/34943431
http://dx.doi.org/10.3390/diagnostics11122195
_version_ 1784620678072238080
author Ueyanagi, Yasushi
Setoyama, Daiki
Kawakami, Daisuke
Mushimoto, Yuichi
Matsumoto, Shinya
Hotta, Taeko
Kang, Dongchon
author_facet Ueyanagi, Yasushi
Setoyama, Daiki
Kawakami, Daisuke
Mushimoto, Yuichi
Matsumoto, Shinya
Hotta, Taeko
Kang, Dongchon
author_sort Ueyanagi, Yasushi
collection PubMed
description Gas chromatography-mass spectrometry has been widely used to analyze hundreds of organic acids in urine to provide a diagnostic basis for organic acidemia. However, it is difficult to operate in clinical laboratories on a daily basis due to sample pretreatment processing. Therefore, we aimed to develop a fully automated system for quantifying serum organic acids using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The pretreatment CLAM-2030 device was connected to an LC-MS/MS system for processing serum under optimized conditions, which included derivatizing serum organic acids using 3-Nitrophenylhydrazine. The derivatized organic acids were separated on a reverse-phase Sceptor HD-C column and detected using negative-ion electrospray ionization multiple reaction monitoring MS. The automated pretreatment-LC-MS/MS system processed serum in less than 1 h and analyzed 19 serum organic acids, which are used to detect organic acidemias. The system exhibited high quantitative sensitivity ranging from approximately 2 to 100 µM with a measurement reproducibility of 10.4% CV. Moreover, a proof-of-concept validation of the system was performed using sera from patients with propionic acidemia (n = 5), methylmalonic acidemia (n = 2), and 3-methylcrotonylglycinuria (n = 1). The levels of marker organic acids specific to each disease were significantly elevated in the sera of the patients compared to those in control samples. The automated pretreatment-LC-MS/MS system can be used as a rapid in-hospital system to measure organic acid levels in serum for the diagnosis of organic acidemias.
format Online
Article
Text
id pubmed-8700112
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-87001122021-12-24 Fully Automated Quantitative Measurement of Serum Organic Acids via LC-MS/MS for the Diagnosis of Organic Acidemias: Establishment of an Automation System and a Proof-of-Concept Validation Ueyanagi, Yasushi Setoyama, Daiki Kawakami, Daisuke Mushimoto, Yuichi Matsumoto, Shinya Hotta, Taeko Kang, Dongchon Diagnostics (Basel) Article Gas chromatography-mass spectrometry has been widely used to analyze hundreds of organic acids in urine to provide a diagnostic basis for organic acidemia. However, it is difficult to operate in clinical laboratories on a daily basis due to sample pretreatment processing. Therefore, we aimed to develop a fully automated system for quantifying serum organic acids using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The pretreatment CLAM-2030 device was connected to an LC-MS/MS system for processing serum under optimized conditions, which included derivatizing serum organic acids using 3-Nitrophenylhydrazine. The derivatized organic acids were separated on a reverse-phase Sceptor HD-C column and detected using negative-ion electrospray ionization multiple reaction monitoring MS. The automated pretreatment-LC-MS/MS system processed serum in less than 1 h and analyzed 19 serum organic acids, which are used to detect organic acidemias. The system exhibited high quantitative sensitivity ranging from approximately 2 to 100 µM with a measurement reproducibility of 10.4% CV. Moreover, a proof-of-concept validation of the system was performed using sera from patients with propionic acidemia (n = 5), methylmalonic acidemia (n = 2), and 3-methylcrotonylglycinuria (n = 1). The levels of marker organic acids specific to each disease were significantly elevated in the sera of the patients compared to those in control samples. The automated pretreatment-LC-MS/MS system can be used as a rapid in-hospital system to measure organic acid levels in serum for the diagnosis of organic acidemias. MDPI 2021-11-25 /pmc/articles/PMC8700112/ /pubmed/34943431 http://dx.doi.org/10.3390/diagnostics11122195 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ueyanagi, Yasushi
Setoyama, Daiki
Kawakami, Daisuke
Mushimoto, Yuichi
Matsumoto, Shinya
Hotta, Taeko
Kang, Dongchon
Fully Automated Quantitative Measurement of Serum Organic Acids via LC-MS/MS for the Diagnosis of Organic Acidemias: Establishment of an Automation System and a Proof-of-Concept Validation
title Fully Automated Quantitative Measurement of Serum Organic Acids via LC-MS/MS for the Diagnosis of Organic Acidemias: Establishment of an Automation System and a Proof-of-Concept Validation
title_full Fully Automated Quantitative Measurement of Serum Organic Acids via LC-MS/MS for the Diagnosis of Organic Acidemias: Establishment of an Automation System and a Proof-of-Concept Validation
title_fullStr Fully Automated Quantitative Measurement of Serum Organic Acids via LC-MS/MS for the Diagnosis of Organic Acidemias: Establishment of an Automation System and a Proof-of-Concept Validation
title_full_unstemmed Fully Automated Quantitative Measurement of Serum Organic Acids via LC-MS/MS for the Diagnosis of Organic Acidemias: Establishment of an Automation System and a Proof-of-Concept Validation
title_short Fully Automated Quantitative Measurement of Serum Organic Acids via LC-MS/MS for the Diagnosis of Organic Acidemias: Establishment of an Automation System and a Proof-of-Concept Validation
title_sort fully automated quantitative measurement of serum organic acids via lc-ms/ms for the diagnosis of organic acidemias: establishment of an automation system and a proof-of-concept validation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8700112/
https://www.ncbi.nlm.nih.gov/pubmed/34943431
http://dx.doi.org/10.3390/diagnostics11122195
work_keys_str_mv AT ueyanagiyasushi fullyautomatedquantitativemeasurementofserumorganicacidsvialcmsmsforthediagnosisoforganicacidemiasestablishmentofanautomationsystemandaproofofconceptvalidation
AT setoyamadaiki fullyautomatedquantitativemeasurementofserumorganicacidsvialcmsmsforthediagnosisoforganicacidemiasestablishmentofanautomationsystemandaproofofconceptvalidation
AT kawakamidaisuke fullyautomatedquantitativemeasurementofserumorganicacidsvialcmsmsforthediagnosisoforganicacidemiasestablishmentofanautomationsystemandaproofofconceptvalidation
AT mushimotoyuichi fullyautomatedquantitativemeasurementofserumorganicacidsvialcmsmsforthediagnosisoforganicacidemiasestablishmentofanautomationsystemandaproofofconceptvalidation
AT matsumotoshinya fullyautomatedquantitativemeasurementofserumorganicacidsvialcmsmsforthediagnosisoforganicacidemiasestablishmentofanautomationsystemandaproofofconceptvalidation
AT hottataeko fullyautomatedquantitativemeasurementofserumorganicacidsvialcmsmsforthediagnosisoforganicacidemiasestablishmentofanautomationsystemandaproofofconceptvalidation
AT kangdongchon fullyautomatedquantitativemeasurementofserumorganicacidsvialcmsmsforthediagnosisoforganicacidemiasestablishmentofanautomationsystemandaproofofconceptvalidation