Initial experience covering 50 consecutive cases of large Impella implantation at a single heart centre

AIMS: Pre‐operative or post‐operative heart failure (HF) and cardiogenic shock of various natures frequently remain refractory to conservative treatment and require mechanical circulatory support. We report our clinical experience with large Impella systems (5.0 or 5.5; i.e. Impella 5+) (Abiomed Inc...