Canal transportation and centering ability of root canals prepared using rotary and reciprocating systems with and without PathFiles in cone-beam computed tomography-based three-dimensional molar prototypes

BACKGROUND: It is important to use instruments that cause minimal changes in the canal path for root canal preparation. There is inadequate literature comparing rotary and reciprocating systems and hand files. No study used three-dimensional printed models to compare rotary, reciprocating, and hand...

Descripción completa

Detalles Bibliográficos
Autores principales: Sunildath, M. Sruthi, Mathew, Josey, George, Liza, Vineet, R. V, Thomas, Priya, John, Dhanya
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2021