Study for Performance Increase of a Extractor Device by Steel Replacement of AISI 304 Steel for AISI 420 Steel

The performance of an extractor device used in the food industry was studied from the development of structural analysis through computational modeling based on finite elements. These analyses considered the mechanical properties of AISI 304 and 420 stainless steels, in addition to the tribological...

Descripción completa

Detalles Bibliográficos
Autores principales: Júnior, Francisco Alves de Lima, Ferreira, Ricardo Artur Sanguinetti, Lima, Rômulo Rocha de Araújo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8746010/
https://www.ncbi.nlm.nih.gov/pubmed/35009426
http://dx.doi.org/10.3390/ma15010280
_version_ 1784630481431560192
author Júnior, Francisco Alves de Lima
Ferreira, Ricardo Artur Sanguinetti
Lima, Rômulo Rocha de Araújo
author_facet Júnior, Francisco Alves de Lima
Ferreira, Ricardo Artur Sanguinetti
Lima, Rômulo Rocha de Araújo
author_sort Júnior, Francisco Alves de Lima
collection PubMed
description The performance of an extractor device used in the food industry was studied from the development of structural analysis through computational modeling based on finite elements. These analyses considered the mechanical properties of AISI 304 and 420 stainless steels, in addition to the tribological aspects of the device in operation. Initially, uniaxial tensile tests were carried out according to the ABNT NBR 6892 standard and hardness tests were carried out according to ASTM E384, E92, and E18 standards. From the mechanical tests, structural analyses were carried out numerically on each of the components of the extractor device. After analyzing all the components, the device was assembled to be tested in operation. The wear and service life of devices made from these two materials were evaluated. From this study, it could be concluded that the extractor device made with AISI 420 stainless steel, in addition to having a lower manufacturing cost, suffered less wear and had an increase in service life of up to 650% compared to the extractor device made with steel stainless steel AISI 304.
format Online
Article
Text
id pubmed-8746010
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-87460102022-01-11 Study for Performance Increase of a Extractor Device by Steel Replacement of AISI 304 Steel for AISI 420 Steel Júnior, Francisco Alves de Lima Ferreira, Ricardo Artur Sanguinetti Lima, Rômulo Rocha de Araújo Materials (Basel) Article The performance of an extractor device used in the food industry was studied from the development of structural analysis through computational modeling based on finite elements. These analyses considered the mechanical properties of AISI 304 and 420 stainless steels, in addition to the tribological aspects of the device in operation. Initially, uniaxial tensile tests were carried out according to the ABNT NBR 6892 standard and hardness tests were carried out according to ASTM E384, E92, and E18 standards. From the mechanical tests, structural analyses were carried out numerically on each of the components of the extractor device. After analyzing all the components, the device was assembled to be tested in operation. The wear and service life of devices made from these two materials were evaluated. From this study, it could be concluded that the extractor device made with AISI 420 stainless steel, in addition to having a lower manufacturing cost, suffered less wear and had an increase in service life of up to 650% compared to the extractor device made with steel stainless steel AISI 304. MDPI 2021-12-30 /pmc/articles/PMC8746010/ /pubmed/35009426 http://dx.doi.org/10.3390/ma15010280 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Júnior, Francisco Alves de Lima
Ferreira, Ricardo Artur Sanguinetti
Lima, Rômulo Rocha de Araújo
Study for Performance Increase of a Extractor Device by Steel Replacement of AISI 304 Steel for AISI 420 Steel
title Study for Performance Increase of a Extractor Device by Steel Replacement of AISI 304 Steel for AISI 420 Steel
title_full Study for Performance Increase of a Extractor Device by Steel Replacement of AISI 304 Steel for AISI 420 Steel
title_fullStr Study for Performance Increase of a Extractor Device by Steel Replacement of AISI 304 Steel for AISI 420 Steel
title_full_unstemmed Study for Performance Increase of a Extractor Device by Steel Replacement of AISI 304 Steel for AISI 420 Steel
title_short Study for Performance Increase of a Extractor Device by Steel Replacement of AISI 304 Steel for AISI 420 Steel
title_sort study for performance increase of a extractor device by steel replacement of aisi 304 steel for aisi 420 steel
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8746010/
https://www.ncbi.nlm.nih.gov/pubmed/35009426
http://dx.doi.org/10.3390/ma15010280
work_keys_str_mv AT juniorfranciscoalvesdelima studyforperformanceincreaseofaextractordevicebysteelreplacementofaisi304steelforaisi420steel
AT ferreiraricardoartursanguinetti studyforperformanceincreaseofaextractordevicebysteelreplacementofaisi304steelforaisi420steel
AT limaromulorochadearaujo studyforperformanceincreaseofaextractordevicebysteelreplacementofaisi304steelforaisi420steel