Cargando…
Study for Performance Increase of a Extractor Device by Steel Replacement of AISI 304 Steel for AISI 420 Steel
The performance of an extractor device used in the food industry was studied from the development of structural analysis through computational modeling based on finite elements. These analyses considered the mechanical properties of AISI 304 and 420 stainless steels, in addition to the tribological...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8746010/ https://www.ncbi.nlm.nih.gov/pubmed/35009426 http://dx.doi.org/10.3390/ma15010280 |
_version_ | 1784630481431560192 |
---|---|
author | Júnior, Francisco Alves de Lima Ferreira, Ricardo Artur Sanguinetti Lima, Rômulo Rocha de Araújo |
author_facet | Júnior, Francisco Alves de Lima Ferreira, Ricardo Artur Sanguinetti Lima, Rômulo Rocha de Araújo |
author_sort | Júnior, Francisco Alves de Lima |
collection | PubMed |
description | The performance of an extractor device used in the food industry was studied from the development of structural analysis through computational modeling based on finite elements. These analyses considered the mechanical properties of AISI 304 and 420 stainless steels, in addition to the tribological aspects of the device in operation. Initially, uniaxial tensile tests were carried out according to the ABNT NBR 6892 standard and hardness tests were carried out according to ASTM E384, E92, and E18 standards. From the mechanical tests, structural analyses were carried out numerically on each of the components of the extractor device. After analyzing all the components, the device was assembled to be tested in operation. The wear and service life of devices made from these two materials were evaluated. From this study, it could be concluded that the extractor device made with AISI 420 stainless steel, in addition to having a lower manufacturing cost, suffered less wear and had an increase in service life of up to 650% compared to the extractor device made with steel stainless steel AISI 304. |
format | Online Article Text |
id | pubmed-8746010 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-87460102022-01-11 Study for Performance Increase of a Extractor Device by Steel Replacement of AISI 304 Steel for AISI 420 Steel Júnior, Francisco Alves de Lima Ferreira, Ricardo Artur Sanguinetti Lima, Rômulo Rocha de Araújo Materials (Basel) Article The performance of an extractor device used in the food industry was studied from the development of structural analysis through computational modeling based on finite elements. These analyses considered the mechanical properties of AISI 304 and 420 stainless steels, in addition to the tribological aspects of the device in operation. Initially, uniaxial tensile tests were carried out according to the ABNT NBR 6892 standard and hardness tests were carried out according to ASTM E384, E92, and E18 standards. From the mechanical tests, structural analyses were carried out numerically on each of the components of the extractor device. After analyzing all the components, the device was assembled to be tested in operation. The wear and service life of devices made from these two materials were evaluated. From this study, it could be concluded that the extractor device made with AISI 420 stainless steel, in addition to having a lower manufacturing cost, suffered less wear and had an increase in service life of up to 650% compared to the extractor device made with steel stainless steel AISI 304. MDPI 2021-12-30 /pmc/articles/PMC8746010/ /pubmed/35009426 http://dx.doi.org/10.3390/ma15010280 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Júnior, Francisco Alves de Lima Ferreira, Ricardo Artur Sanguinetti Lima, Rômulo Rocha de Araújo Study for Performance Increase of a Extractor Device by Steel Replacement of AISI 304 Steel for AISI 420 Steel |
title | Study for Performance Increase of a Extractor Device by Steel Replacement of AISI 304 Steel for AISI 420 Steel |
title_full | Study for Performance Increase of a Extractor Device by Steel Replacement of AISI 304 Steel for AISI 420 Steel |
title_fullStr | Study for Performance Increase of a Extractor Device by Steel Replacement of AISI 304 Steel for AISI 420 Steel |
title_full_unstemmed | Study for Performance Increase of a Extractor Device by Steel Replacement of AISI 304 Steel for AISI 420 Steel |
title_short | Study for Performance Increase of a Extractor Device by Steel Replacement of AISI 304 Steel for AISI 420 Steel |
title_sort | study for performance increase of a extractor device by steel replacement of aisi 304 steel for aisi 420 steel |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8746010/ https://www.ncbi.nlm.nih.gov/pubmed/35009426 http://dx.doi.org/10.3390/ma15010280 |
work_keys_str_mv | AT juniorfranciscoalvesdelima studyforperformanceincreaseofaextractordevicebysteelreplacementofaisi304steelforaisi420steel AT ferreiraricardoartursanguinetti studyforperformanceincreaseofaextractordevicebysteelreplacementofaisi304steelforaisi420steel AT limaromulorochadearaujo studyforperformanceincreaseofaextractordevicebysteelreplacementofaisi304steelforaisi420steel |