Cargando…
Control of the Longitudinal Compression and Transverse Focus of Ultrafast Electron Beam for Detecting the Transient Evolution of Materials
Ultrafast detection is an effective method to reveal the transient evolution mechanism of materials. Compared with ultra-fast X-ray diffraction (XRD), the ultra-fast electron beam is increasingly adopted because the larger scattering cross-section is less harmful to the sample. The keV single-shot u...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8781741/ https://www.ncbi.nlm.nih.gov/pubmed/35057289 http://dx.doi.org/10.3390/ma15020571 |
_version_ | 1784638151748222976 |
---|---|
author | Cai, Xintian Wang, Zhen Ji, Chaoyue Wang, Xuan Gan, Zhiyin Liu, Sheng |
author_facet | Cai, Xintian Wang, Zhen Ji, Chaoyue Wang, Xuan Gan, Zhiyin Liu, Sheng |
author_sort | Cai, Xintian |
collection | PubMed |
description | Ultrafast detection is an effective method to reveal the transient evolution mechanism of materials. Compared with ultra-fast X-ray diffraction (XRD), the ultra-fast electron beam is increasingly adopted because the larger scattering cross-section is less harmful to the sample. The keV single-shot ultra-fast electron imaging system has been widely used with its compact structure and easy integration. To achieve both the single pulse imaging and the ultra-high temporal resolution, magnetic lenses are typically used for transverse focus to increase signal strength, while radio frequency (RF) cavities are generally utilized for longitudinal compression to improve temporal resolution. However, the detection signal is relatively weak due to the Coulomb force between electrons. Moreover, the effect of RF compression on the transverse focus is usually ignored. We established a particle tracking model to simulate the electron pulse propagation based on the 1-D fluid equation and the 2-D mean-field equation. Under considering the relativity effect and Coulomb force, the impact of RF compression on the transverse focus was studied by solving the fifth-order Rung–Kutta equation. The results show that the RF cavity is not only a key component of longitudinal compression but also affects the transverse focusing. While the effect of transverse focus on longitudinal duration is negligible. By adjusting the position and compression strength of the RF cavity, the beam spot radius can be reduced from 100 [Formula: see text] m to 30 [Formula: see text] m under the simulation conditions in this paper. When the number of single pulse electrons remains constant, the electrons density incident on the sample could be increased from [Formula: see text] [Formula: see text] to [Formula: see text] [Formula: see text] , which is 11 times the original. The larger the electron density incident on the sample, the greater the signal intensity, which is more conducive to detecting the transient evolution of the material. |
format | Online Article Text |
id | pubmed-8781741 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-87817412022-01-22 Control of the Longitudinal Compression and Transverse Focus of Ultrafast Electron Beam for Detecting the Transient Evolution of Materials Cai, Xintian Wang, Zhen Ji, Chaoyue Wang, Xuan Gan, Zhiyin Liu, Sheng Materials (Basel) Article Ultrafast detection is an effective method to reveal the transient evolution mechanism of materials. Compared with ultra-fast X-ray diffraction (XRD), the ultra-fast electron beam is increasingly adopted because the larger scattering cross-section is less harmful to the sample. The keV single-shot ultra-fast electron imaging system has been widely used with its compact structure and easy integration. To achieve both the single pulse imaging and the ultra-high temporal resolution, magnetic lenses are typically used for transverse focus to increase signal strength, while radio frequency (RF) cavities are generally utilized for longitudinal compression to improve temporal resolution. However, the detection signal is relatively weak due to the Coulomb force between electrons. Moreover, the effect of RF compression on the transverse focus is usually ignored. We established a particle tracking model to simulate the electron pulse propagation based on the 1-D fluid equation and the 2-D mean-field equation. Under considering the relativity effect and Coulomb force, the impact of RF compression on the transverse focus was studied by solving the fifth-order Rung–Kutta equation. The results show that the RF cavity is not only a key component of longitudinal compression but also affects the transverse focusing. While the effect of transverse focus on longitudinal duration is negligible. By adjusting the position and compression strength of the RF cavity, the beam spot radius can be reduced from 100 [Formula: see text] m to 30 [Formula: see text] m under the simulation conditions in this paper. When the number of single pulse electrons remains constant, the electrons density incident on the sample could be increased from [Formula: see text] [Formula: see text] to [Formula: see text] [Formula: see text] , which is 11 times the original. The larger the electron density incident on the sample, the greater the signal intensity, which is more conducive to detecting the transient evolution of the material. MDPI 2022-01-13 /pmc/articles/PMC8781741/ /pubmed/35057289 http://dx.doi.org/10.3390/ma15020571 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Cai, Xintian Wang, Zhen Ji, Chaoyue Wang, Xuan Gan, Zhiyin Liu, Sheng Control of the Longitudinal Compression and Transverse Focus of Ultrafast Electron Beam for Detecting the Transient Evolution of Materials |
title | Control of the Longitudinal Compression and Transverse Focus of Ultrafast Electron Beam for Detecting the Transient Evolution of Materials |
title_full | Control of the Longitudinal Compression and Transverse Focus of Ultrafast Electron Beam for Detecting the Transient Evolution of Materials |
title_fullStr | Control of the Longitudinal Compression and Transverse Focus of Ultrafast Electron Beam for Detecting the Transient Evolution of Materials |
title_full_unstemmed | Control of the Longitudinal Compression and Transverse Focus of Ultrafast Electron Beam for Detecting the Transient Evolution of Materials |
title_short | Control of the Longitudinal Compression and Transverse Focus of Ultrafast Electron Beam for Detecting the Transient Evolution of Materials |
title_sort | control of the longitudinal compression and transverse focus of ultrafast electron beam for detecting the transient evolution of materials |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8781741/ https://www.ncbi.nlm.nih.gov/pubmed/35057289 http://dx.doi.org/10.3390/ma15020571 |
work_keys_str_mv | AT caixintian controlofthelongitudinalcompressionandtransversefocusofultrafastelectronbeamfordetectingthetransientevolutionofmaterials AT wangzhen controlofthelongitudinalcompressionandtransversefocusofultrafastelectronbeamfordetectingthetransientevolutionofmaterials AT jichaoyue controlofthelongitudinalcompressionandtransversefocusofultrafastelectronbeamfordetectingthetransientevolutionofmaterials AT wangxuan controlofthelongitudinalcompressionandtransversefocusofultrafastelectronbeamfordetectingthetransientevolutionofmaterials AT ganzhiyin controlofthelongitudinalcompressionandtransversefocusofultrafastelectronbeamfordetectingthetransientevolutionofmaterials AT liusheng controlofthelongitudinalcompressionandtransversefocusofultrafastelectronbeamfordetectingthetransientevolutionofmaterials |