Cargando…
PLL-Based Readout Circuit for SiC-MOS Capacitor Hydrogen Sensors in Industrial Environments
For proper operation in real industrial conditions, gas sensors require readout circuits which offer accuracy, noise robustness, energy efficiency and portability. We present an innovative, dedicated readout circuit with a phase locked loop (PLL) architecture for SiC-MOS capacitor sensors. A hydroge...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8879939/ https://www.ncbi.nlm.nih.gov/pubmed/35214371 http://dx.doi.org/10.3390/s22041462 |