Cargando…
Optimization and Effect of Water Hardness for the Production of Slightly Acidic Electrolyzed Water on Sanitization Efficacy
Slightly acidic electrolyzed water (SAEW) has been recently proposed as a novel promising sanitizer and cleaner in the agricultural and food industries. However, several factors, including water hardness, were considered to strongly affect the physical properties and sanitization efficacy of SAEW. T...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8924475/ https://www.ncbi.nlm.nih.gov/pubmed/35308354 http://dx.doi.org/10.3389/fmicb.2022.816671 |
_version_ | 1784669864181366784 |
---|---|
author | Yan, Pianpian Jo, Hyeon-yeong Chelliah, Ramachandran Jo, Kyoung hee Woo, Nam Chan Wook, Min Seung Oh, Deog Hwan |
author_facet | Yan, Pianpian Jo, Hyeon-yeong Chelliah, Ramachandran Jo, Kyoung hee Woo, Nam Chan Wook, Min Seung Oh, Deog Hwan |
author_sort | Yan, Pianpian |
collection | PubMed |
description | Slightly acidic electrolyzed water (SAEW) has been recently proposed as a novel promising sanitizer and cleaner in the agricultural and food industries. However, several factors, including water hardness, were considered to strongly affect the physical properties and sanitization efficacy of SAEW. To study the effect of water hardness on the SAEW production, we evaluated the production properties and sanitization effect of SAEW, which was generated from water sources in 16 representatively geographical locations of South Korea. The results showed that the hardness of water sources from Kangwon-do, Jeollanam-do, and Daegu was 22–41 ppm; that from Busan, Gyeongnam-do, Gwangju Bukgu was 80–443 ppm, and that from seven other locations was 41–79 ppm. SAEW is produced from water hardness less than 50 ppm and greater than 80 ppm was beyond the accepted pH range (5.0–6.5). Notably, high-hardness water (>80 ppm) containing 5% HCl could be used to produce SAEW with accepted pH. The SAEW generated from low-hardness water with additions of 2% HCl and 2 M NaCl at 7 A showed accepted pH and higher germicidal effect. Furthermore, SAEW with the available chlorine concentration of 27–41 mg/L for 1 min was sufficient to completely inactivate non–spore-forming foodborne pathogens. Sanitization efficacy was not markedly affected by storage conditions for SAEW at 40 ppm. Our results demonstrated that the degree of water hardness is an important factor in the production of SAEW, which would provide a foundation for commercial application of SAEW. |
format | Online Article Text |
id | pubmed-8924475 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-89244752022-03-17 Optimization and Effect of Water Hardness for the Production of Slightly Acidic Electrolyzed Water on Sanitization Efficacy Yan, Pianpian Jo, Hyeon-yeong Chelliah, Ramachandran Jo, Kyoung hee Woo, Nam Chan Wook, Min Seung Oh, Deog Hwan Front Microbiol Microbiology Slightly acidic electrolyzed water (SAEW) has been recently proposed as a novel promising sanitizer and cleaner in the agricultural and food industries. However, several factors, including water hardness, were considered to strongly affect the physical properties and sanitization efficacy of SAEW. To study the effect of water hardness on the SAEW production, we evaluated the production properties and sanitization effect of SAEW, which was generated from water sources in 16 representatively geographical locations of South Korea. The results showed that the hardness of water sources from Kangwon-do, Jeollanam-do, and Daegu was 22–41 ppm; that from Busan, Gyeongnam-do, Gwangju Bukgu was 80–443 ppm, and that from seven other locations was 41–79 ppm. SAEW is produced from water hardness less than 50 ppm and greater than 80 ppm was beyond the accepted pH range (5.0–6.5). Notably, high-hardness water (>80 ppm) containing 5% HCl could be used to produce SAEW with accepted pH. The SAEW generated from low-hardness water with additions of 2% HCl and 2 M NaCl at 7 A showed accepted pH and higher germicidal effect. Furthermore, SAEW with the available chlorine concentration of 27–41 mg/L for 1 min was sufficient to completely inactivate non–spore-forming foodborne pathogens. Sanitization efficacy was not markedly affected by storage conditions for SAEW at 40 ppm. Our results demonstrated that the degree of water hardness is an important factor in the production of SAEW, which would provide a foundation for commercial application of SAEW. Frontiers Media S.A. 2022-03-02 /pmc/articles/PMC8924475/ /pubmed/35308354 http://dx.doi.org/10.3389/fmicb.2022.816671 Text en Copyright © 2022 Yan, Jo, Chelliah, Jo, Woo, Wook and Oh. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Microbiology Yan, Pianpian Jo, Hyeon-yeong Chelliah, Ramachandran Jo, Kyoung hee Woo, Nam Chan Wook, Min Seung Oh, Deog Hwan Optimization and Effect of Water Hardness for the Production of Slightly Acidic Electrolyzed Water on Sanitization Efficacy |
title | Optimization and Effect of Water Hardness for the Production of Slightly Acidic Electrolyzed Water on Sanitization Efficacy |
title_full | Optimization and Effect of Water Hardness for the Production of Slightly Acidic Electrolyzed Water on Sanitization Efficacy |
title_fullStr | Optimization and Effect of Water Hardness for the Production of Slightly Acidic Electrolyzed Water on Sanitization Efficacy |
title_full_unstemmed | Optimization and Effect of Water Hardness for the Production of Slightly Acidic Electrolyzed Water on Sanitization Efficacy |
title_short | Optimization and Effect of Water Hardness for the Production of Slightly Acidic Electrolyzed Water on Sanitization Efficacy |
title_sort | optimization and effect of water hardness for the production of slightly acidic electrolyzed water on sanitization efficacy |
topic | Microbiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8924475/ https://www.ncbi.nlm.nih.gov/pubmed/35308354 http://dx.doi.org/10.3389/fmicb.2022.816671 |
work_keys_str_mv | AT yanpianpian optimizationandeffectofwaterhardnessfortheproductionofslightlyacidicelectrolyzedwateronsanitizationefficacy AT johyeonyeong optimizationandeffectofwaterhardnessfortheproductionofslightlyacidicelectrolyzedwateronsanitizationefficacy AT chelliahramachandran optimizationandeffectofwaterhardnessfortheproductionofslightlyacidicelectrolyzedwateronsanitizationefficacy AT jokyounghee optimizationandeffectofwaterhardnessfortheproductionofslightlyacidicelectrolyzedwateronsanitizationefficacy AT woonamchan optimizationandeffectofwaterhardnessfortheproductionofslightlyacidicelectrolyzedwateronsanitizationefficacy AT wookminseung optimizationandeffectofwaterhardnessfortheproductionofslightlyacidicelectrolyzedwateronsanitizationefficacy AT ohdeoghwan optimizationandeffectofwaterhardnessfortheproductionofslightlyacidicelectrolyzedwateronsanitizationefficacy |