Cargando…

Feasibility of Constructing an Automatic Meniscus Injury Detection Model Based on Dual-Mode Magnetic Resonance Imaging (MRI) Radiomics of the Knee Joint

OBJECTIVE: To explore the feasibility of automatically detecting the degree of meniscus injury by radiomics fusion of dual-mode magnetic resonance imaging (MRI) features of sagittal and coronal planes of the knee joint. METHODS: This retrospective study included 164 arthroscopically confirmed menisc...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Yi, Li, Yuanzhe, Huang, Meiling, Lai, Qingquan, Huang, Jing, Chen, Jiayang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8983204/
https://www.ncbi.nlm.nih.gov/pubmed/35392588
http://dx.doi.org/10.1155/2022/2155132