Cargando…

Stress stability study of simeprevir, a hepatitis C virus inhibitor, using feasible TLC-spectro-densitometry: application to pharmaceutical dosage form and human plasma

Simeprevir is one of the newest direct action anti-hepatitis C drugs. In the present work, a simple, highly selective and stability-indicating, high-performance thin-layer chromatography (HPTLC) method is proposed and validated for the assay of simeprevir both in pharmaceutical dosage form and spike...

Descripción completa

Detalles Bibliográficos
Autores principales: Mohammed, Bassam Shaaban, Hamad, Amal E., Derayea, Sayed M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society of Chemistry 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9054297/
https://www.ncbi.nlm.nih.gov/pubmed/35518774
http://dx.doi.org/10.1039/d0ra01172j
_version_ 1784697159925366784
author Mohammed, Bassam Shaaban
Hamad, Amal E.
Derayea, Sayed M.
author_facet Mohammed, Bassam Shaaban
Hamad, Amal E.
Derayea, Sayed M.
author_sort Mohammed, Bassam Shaaban
collection PubMed
description Simeprevir is one of the newest direct action anti-hepatitis C drugs. In the present work, a simple, highly selective and stability-indicating, high-performance thin-layer chromatography (HPTLC) method is proposed and validated for the assay of simeprevir both in pharmaceutical dosage form and spiked human plasma. The method used silica gel 60 F(254) coated HPTLC aluminum plates as the stationary phase. The mobile phase system was ethyl acetate-hexane-methanol (5 : 4 : 1, v/v/v). The wavelength for both detection and quantitation was set at 288 nm. This system was found to give a compact spot of simeprevir; the retardation factor (R(F)) value was 0.67 ± 0.02. The guidelines of the International Conference on Harmonization were followed to validate the proposed analytical method, and the results were acceptable. The calibration curve was linear over the range of 80–1000 ng per spot. The limit of detection was 19.0 ng per spot, and the limit of quantitation was 57.0 ng per spot. The drug was subjected to various stress conditions including hydrolytic, oxidative and UV-induced resulting in varying degrees of degradation. The results showed that the proposed method could efficiently separate the degradation products from the intact drug and allow its satisfactory quantitation. The proposed method was employed successfully for the accurate and reproducible analysis of the pharmaceutical preparation and human plasma containing the drug. The proposed method's precision and accuracy were statistically similar to those of a reported method.
format Online
Article
Text
id pubmed-9054297
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-90542972022-05-04 Stress stability study of simeprevir, a hepatitis C virus inhibitor, using feasible TLC-spectro-densitometry: application to pharmaceutical dosage form and human plasma Mohammed, Bassam Shaaban Hamad, Amal E. Derayea, Sayed M. RSC Adv Chemistry Simeprevir is one of the newest direct action anti-hepatitis C drugs. In the present work, a simple, highly selective and stability-indicating, high-performance thin-layer chromatography (HPTLC) method is proposed and validated for the assay of simeprevir both in pharmaceutical dosage form and spiked human plasma. The method used silica gel 60 F(254) coated HPTLC aluminum plates as the stationary phase. The mobile phase system was ethyl acetate-hexane-methanol (5 : 4 : 1, v/v/v). The wavelength for both detection and quantitation was set at 288 nm. This system was found to give a compact spot of simeprevir; the retardation factor (R(F)) value was 0.67 ± 0.02. The guidelines of the International Conference on Harmonization were followed to validate the proposed analytical method, and the results were acceptable. The calibration curve was linear over the range of 80–1000 ng per spot. The limit of detection was 19.0 ng per spot, and the limit of quantitation was 57.0 ng per spot. The drug was subjected to various stress conditions including hydrolytic, oxidative and UV-induced resulting in varying degrees of degradation. The results showed that the proposed method could efficiently separate the degradation products from the intact drug and allow its satisfactory quantitation. The proposed method was employed successfully for the accurate and reproducible analysis of the pharmaceutical preparation and human plasma containing the drug. The proposed method's precision and accuracy were statistically similar to those of a reported method. The Royal Society of Chemistry 2020-06-03 /pmc/articles/PMC9054297/ /pubmed/35518774 http://dx.doi.org/10.1039/d0ra01172j Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by/3.0/
spellingShingle Chemistry
Mohammed, Bassam Shaaban
Hamad, Amal E.
Derayea, Sayed M.
Stress stability study of simeprevir, a hepatitis C virus inhibitor, using feasible TLC-spectro-densitometry: application to pharmaceutical dosage form and human plasma
title Stress stability study of simeprevir, a hepatitis C virus inhibitor, using feasible TLC-spectro-densitometry: application to pharmaceutical dosage form and human plasma
title_full Stress stability study of simeprevir, a hepatitis C virus inhibitor, using feasible TLC-spectro-densitometry: application to pharmaceutical dosage form and human plasma
title_fullStr Stress stability study of simeprevir, a hepatitis C virus inhibitor, using feasible TLC-spectro-densitometry: application to pharmaceutical dosage form and human plasma
title_full_unstemmed Stress stability study of simeprevir, a hepatitis C virus inhibitor, using feasible TLC-spectro-densitometry: application to pharmaceutical dosage form and human plasma
title_short Stress stability study of simeprevir, a hepatitis C virus inhibitor, using feasible TLC-spectro-densitometry: application to pharmaceutical dosage form and human plasma
title_sort stress stability study of simeprevir, a hepatitis c virus inhibitor, using feasible tlc-spectro-densitometry: application to pharmaceutical dosage form and human plasma
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9054297/
https://www.ncbi.nlm.nih.gov/pubmed/35518774
http://dx.doi.org/10.1039/d0ra01172j
work_keys_str_mv AT mohammedbassamshaaban stressstabilitystudyofsimeprevirahepatitiscvirusinhibitorusingfeasibletlcspectrodensitometryapplicationtopharmaceuticaldosageformandhumanplasma
AT hamadamale stressstabilitystudyofsimeprevirahepatitiscvirusinhibitorusingfeasibletlcspectrodensitometryapplicationtopharmaceuticaldosageformandhumanplasma
AT derayeasayedm stressstabilitystudyofsimeprevirahepatitiscvirusinhibitorusingfeasibletlcspectrodensitometryapplicationtopharmaceuticaldosageformandhumanplasma