Clinical and Anatomical Factors Affecting Recurrent Laryngeal Nerve Paralysis During Thyroidectomy via Intraoperative Nerve Monitorization
BACKGROUND: Despite all the technical developments in thyroidectomy and the use of intraoperative nerve monitorization (IONM), recurrent laryngeal nerve (RLN) paralysis may still occur. We aimed to evaluate the effects of anatomical variations, clinical features, and intervention type on RLN paralys...