Paradoxical cause of weaning failure: Post tracheostomy foreign body causing non‐resolving pneumonia with worsening failure to wean
The Percutaneous technique for tracheostomy has become the standard procedure, due to its ease in placement, minimal complications, and has almost replaced the traditional open (surgical) tracheostomy in intensive care units. We describe a case of broken tracheal cartilage which slipped into the tra...