Cargando…
Polyimide-Based High-Performance Film Bulk Acoustic Resonator Humidity Sensor and Its Application in Real-Time Human Respiration Monitoring
Respiration monitoring is vital for human health assessment. Humidity sensing is a promising way to establish a relationship between human respiration and electrical signal. This paper presents a polyimide-based film bulk acoustic resonator (PI-FBAR) humidity sensor operating in resonant frequency a...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9143046/ https://www.ncbi.nlm.nih.gov/pubmed/35630225 http://dx.doi.org/10.3390/mi13050758 |
_version_ | 1784715708737781760 |
---|---|
author | Zhu, Yusi Xia, Pan Liu, Jihang Fang, Zhen Du, Lidong Zhao, Zhan |
author_facet | Zhu, Yusi Xia, Pan Liu, Jihang Fang, Zhen Du, Lidong Zhao, Zhan |
author_sort | Zhu, Yusi |
collection | PubMed |
description | Respiration monitoring is vital for human health assessment. Humidity sensing is a promising way to establish a relationship between human respiration and electrical signal. This paper presents a polyimide-based film bulk acoustic resonator (PI-FBAR) humidity sensor operating in resonant frequency and reflection coefficient S(11) dual-parameter with high sensitivity and stability, and it is applied in real-time human respiration monitoring for the first time. Both these two parameters can be used to sense different breathing conditions, such as normal breathing and deep breathing, and breathing with different rates such as normal breathing, slow breathing, apnea, and fast breathing. Experimental results also indicate that the proposed humidity sensor has potential applications in predicting the fitness of individual and in the medical field for detecting body fluids loss and daily water intake warning. The respiratory rates measured by our proposed PI-FBAR humidity sensor operating in frequency mode and S(11) mode have Pearson correlation of up to 0.975 and 0.982 with that measured by the clinical monitor, respectively. Bland–Altman method analysis results further revealed that both S(11) and frequency response are in good agreement with clinical monitor. The proposed sensor combines the advantages of non-invasiveness, high sensitivity and high stability, and it has great potential in human health monitoring. |
format | Online Article Text |
id | pubmed-9143046 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-91430462022-05-29 Polyimide-Based High-Performance Film Bulk Acoustic Resonator Humidity Sensor and Its Application in Real-Time Human Respiration Monitoring Zhu, Yusi Xia, Pan Liu, Jihang Fang, Zhen Du, Lidong Zhao, Zhan Micromachines (Basel) Article Respiration monitoring is vital for human health assessment. Humidity sensing is a promising way to establish a relationship between human respiration and electrical signal. This paper presents a polyimide-based film bulk acoustic resonator (PI-FBAR) humidity sensor operating in resonant frequency and reflection coefficient S(11) dual-parameter with high sensitivity and stability, and it is applied in real-time human respiration monitoring for the first time. Both these two parameters can be used to sense different breathing conditions, such as normal breathing and deep breathing, and breathing with different rates such as normal breathing, slow breathing, apnea, and fast breathing. Experimental results also indicate that the proposed humidity sensor has potential applications in predicting the fitness of individual and in the medical field for detecting body fluids loss and daily water intake warning. The respiratory rates measured by our proposed PI-FBAR humidity sensor operating in frequency mode and S(11) mode have Pearson correlation of up to 0.975 and 0.982 with that measured by the clinical monitor, respectively. Bland–Altman method analysis results further revealed that both S(11) and frequency response are in good agreement with clinical monitor. The proposed sensor combines the advantages of non-invasiveness, high sensitivity and high stability, and it has great potential in human health monitoring. MDPI 2022-05-11 /pmc/articles/PMC9143046/ /pubmed/35630225 http://dx.doi.org/10.3390/mi13050758 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Zhu, Yusi Xia, Pan Liu, Jihang Fang, Zhen Du, Lidong Zhao, Zhan Polyimide-Based High-Performance Film Bulk Acoustic Resonator Humidity Sensor and Its Application in Real-Time Human Respiration Monitoring |
title | Polyimide-Based High-Performance Film Bulk Acoustic Resonator Humidity Sensor and Its Application in Real-Time Human Respiration Monitoring |
title_full | Polyimide-Based High-Performance Film Bulk Acoustic Resonator Humidity Sensor and Its Application in Real-Time Human Respiration Monitoring |
title_fullStr | Polyimide-Based High-Performance Film Bulk Acoustic Resonator Humidity Sensor and Its Application in Real-Time Human Respiration Monitoring |
title_full_unstemmed | Polyimide-Based High-Performance Film Bulk Acoustic Resonator Humidity Sensor and Its Application in Real-Time Human Respiration Monitoring |
title_short | Polyimide-Based High-Performance Film Bulk Acoustic Resonator Humidity Sensor and Its Application in Real-Time Human Respiration Monitoring |
title_sort | polyimide-based high-performance film bulk acoustic resonator humidity sensor and its application in real-time human respiration monitoring |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9143046/ https://www.ncbi.nlm.nih.gov/pubmed/35630225 http://dx.doi.org/10.3390/mi13050758 |
work_keys_str_mv | AT zhuyusi polyimidebasedhighperformancefilmbulkacousticresonatorhumiditysensoranditsapplicationinrealtimehumanrespirationmonitoring AT xiapan polyimidebasedhighperformancefilmbulkacousticresonatorhumiditysensoranditsapplicationinrealtimehumanrespirationmonitoring AT liujihang polyimidebasedhighperformancefilmbulkacousticresonatorhumiditysensoranditsapplicationinrealtimehumanrespirationmonitoring AT fangzhen polyimidebasedhighperformancefilmbulkacousticresonatorhumiditysensoranditsapplicationinrealtimehumanrespirationmonitoring AT dulidong polyimidebasedhighperformancefilmbulkacousticresonatorhumiditysensoranditsapplicationinrealtimehumanrespirationmonitoring AT zhaozhan polyimidebasedhighperformancefilmbulkacousticresonatorhumiditysensoranditsapplicationinrealtimehumanrespirationmonitoring |