Cargando…
1-(4-Hydroxyphenyl)-2H-tetrazole-5-thione as a leveler for acid copper electroplating of microvia
Microvia filling by copper electroplating was performed using plating solution with 1-(4-hydroxyphenyl)-2H-tetrazole-5-thione (HPTT) as the leveler. Galvanostatic Measurements (GMs), Linear Sweep Voltammetry (LSV) and Electrochemical Impedance Spectroscopy (EIS) tests were carried out to investigate...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Royal Society of Chemistry
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9152711/ https://www.ncbi.nlm.nih.gov/pubmed/35733656 http://dx.doi.org/10.1039/d2ra02274e |
_version_ | 1784717702868238336 |
---|---|
author | Teng, Xulingjie Tao, Zhihua Long, Zhiyuan Liu, Guanting Tao, Xuefei |
author_facet | Teng, Xulingjie Tao, Zhihua Long, Zhiyuan Liu, Guanting Tao, Xuefei |
author_sort | Teng, Xulingjie |
collection | PubMed |
description | Microvia filling by copper electroplating was performed using plating solution with 1-(4-hydroxyphenyl)-2H-tetrazole-5-thione (HPTT) as the leveler. Galvanostatic Measurements (GMs), Linear Sweep Voltammetry (LSV) and Electrochemical Impedance Spectroscopy (EIS) tests were carried out to investigate the electrochemical behaviors of HPTT and its synergistic effect with other additives, in comparison with 1-phenyltetrazole-5-thione (PMT). GMs showed a convection-dependent interaction between PEP and HPTT. LSV and EIS tests indicated both HPTT and PMT enhanced the inhibition effect of PEP, and the synergistic effect of HPTT and PEP was stronger than that of PMT. Cross-section images illustrated the filling rate of the microvia with a 150 μm diameter and a 75 μm depth was 95.6% in 60 minutes with HPTT as the leveler. Frontier Molecular Orbitals (FMO) and Electrostatic Potential (ESP) of HPTT and PMT using quantum chemical calculations predicted the reaction sites for electrophilic and nucleophilic attack. Quantum chemical calculations suggested that HPTT is easier than PMT to bond to a copper surface and PEP. |
format | Online Article Text |
id | pubmed-9152711 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | The Royal Society of Chemistry |
record_format | MEDLINE/PubMed |
spelling | pubmed-91527112022-06-21 1-(4-Hydroxyphenyl)-2H-tetrazole-5-thione as a leveler for acid copper electroplating of microvia Teng, Xulingjie Tao, Zhihua Long, Zhiyuan Liu, Guanting Tao, Xuefei RSC Adv Chemistry Microvia filling by copper electroplating was performed using plating solution with 1-(4-hydroxyphenyl)-2H-tetrazole-5-thione (HPTT) as the leveler. Galvanostatic Measurements (GMs), Linear Sweep Voltammetry (LSV) and Electrochemical Impedance Spectroscopy (EIS) tests were carried out to investigate the electrochemical behaviors of HPTT and its synergistic effect with other additives, in comparison with 1-phenyltetrazole-5-thione (PMT). GMs showed a convection-dependent interaction between PEP and HPTT. LSV and EIS tests indicated both HPTT and PMT enhanced the inhibition effect of PEP, and the synergistic effect of HPTT and PEP was stronger than that of PMT. Cross-section images illustrated the filling rate of the microvia with a 150 μm diameter and a 75 μm depth was 95.6% in 60 minutes with HPTT as the leveler. Frontier Molecular Orbitals (FMO) and Electrostatic Potential (ESP) of HPTT and PMT using quantum chemical calculations predicted the reaction sites for electrophilic and nucleophilic attack. Quantum chemical calculations suggested that HPTT is easier than PMT to bond to a copper surface and PEP. The Royal Society of Chemistry 2022-05-31 /pmc/articles/PMC9152711/ /pubmed/35733656 http://dx.doi.org/10.1039/d2ra02274e Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by-nc/3.0/ |
spellingShingle | Chemistry Teng, Xulingjie Tao, Zhihua Long, Zhiyuan Liu, Guanting Tao, Xuefei 1-(4-Hydroxyphenyl)-2H-tetrazole-5-thione as a leveler for acid copper electroplating of microvia |
title | 1-(4-Hydroxyphenyl)-2H-tetrazole-5-thione as a leveler for acid copper electroplating of microvia |
title_full | 1-(4-Hydroxyphenyl)-2H-tetrazole-5-thione as a leveler for acid copper electroplating of microvia |
title_fullStr | 1-(4-Hydroxyphenyl)-2H-tetrazole-5-thione as a leveler for acid copper electroplating of microvia |
title_full_unstemmed | 1-(4-Hydroxyphenyl)-2H-tetrazole-5-thione as a leveler for acid copper electroplating of microvia |
title_short | 1-(4-Hydroxyphenyl)-2H-tetrazole-5-thione as a leveler for acid copper electroplating of microvia |
title_sort | 1-(4-hydroxyphenyl)-2h-tetrazole-5-thione as a leveler for acid copper electroplating of microvia |
topic | Chemistry |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9152711/ https://www.ncbi.nlm.nih.gov/pubmed/35733656 http://dx.doi.org/10.1039/d2ra02274e |
work_keys_str_mv | AT tengxulingjie 14hydroxyphenyl2htetrazole5thioneasalevelerforacidcopperelectroplatingofmicrovia AT taozhihua 14hydroxyphenyl2htetrazole5thioneasalevelerforacidcopperelectroplatingofmicrovia AT longzhiyuan 14hydroxyphenyl2htetrazole5thioneasalevelerforacidcopperelectroplatingofmicrovia AT liuguanting 14hydroxyphenyl2htetrazole5thioneasalevelerforacidcopperelectroplatingofmicrovia AT taoxuefei 14hydroxyphenyl2htetrazole5thioneasalevelerforacidcopperelectroplatingofmicrovia |