Analysis of Discrepancies Between Pulse Oximetry and Arterial Oxygen Saturation Measurements by Race and Ethnicity and Association With Organ Dysfunction and Mortality

IMPORTANCE: Discrepancies in oxygen saturation measured by pulse oximetry (Spo(2)), when compared with arterial oxygen saturation (Sao(2)) measured by arterial blood gas (ABG), may differentially affect patients according to race and ethnicity. However, the association of these disparities with heal...

Descripción completa

Detalles Bibliográficos
Autores principales: Wong, An-Kwok Ian, Charpignon, Marie, Kim, Han, Josef, Christopher, de Hond, Anne A. H., Fojas, Jhalique Jane, Tabaie, Azade, Liu, Xiaoli, Mireles-Cabodevila, Eduardo, Carvalho, Leandro, Kamaleswaran, Rishikesan, Madushani, R. W. M. A., Adhikari, Lasith, Holder, Andre L., Steyerberg, Ewout W., Buchman, Timothy G., Lough, Mary E., Celi, Leo Anthony
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Medical Association 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9178439/
https://www.ncbi.nlm.nih.gov/pubmed/34730820
http://dx.doi.org/10.1001/jamanetworkopen.2021.31674