Cargando…

Ergonomic Design and Performance Evaluation of H-Suit for Human Walking

A soft exoskeleton for the hip flexion, named H-Suit, is developed to improve the walking endurance of lower limbs, delay muscle fatigue and reduce the activation level of hip flexors. Based on the kinematics and biomechanics of the hip joints, the ergonomic design of the H-Suit system is clearly pr...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Leiyu, Jiao, Zhenxing, He, Yandong, Su, Peng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9227600/
https://www.ncbi.nlm.nih.gov/pubmed/35744439
http://dx.doi.org/10.3390/mi13060825
_version_ 1784734223624568832
author Zhang, Leiyu
Jiao, Zhenxing
He, Yandong
Su, Peng
author_facet Zhang, Leiyu
Jiao, Zhenxing
He, Yandong
Su, Peng
author_sort Zhang, Leiyu
collection PubMed
description A soft exoskeleton for the hip flexion, named H-Suit, is developed to improve the walking endurance of lower limbs, delay muscle fatigue and reduce the activation level of hip flexors. Based on the kinematics and biomechanics of the hip joints, the ergonomic design of the H-Suit system is clearly presented and the prototype was developed. The profile of the auxiliary forces is planned in the auxiliary range where the forces start at the minimum hip angle, reach the maximum (120 N) and end at 90% of each gait cycle. The desired displacements of the traction unit which consist of the natural and elastic displacements of the steel cables are obtained by the experimental method. An assistance strategy is proposed to track the profile of the auxiliary forces by dynamically adjusting the compensation displacement L(c) and the hold time Δt. The influences of the variables L(c) and Δt on the natural gaits and auxiliary forces have been revealed and analyzed. The real profile of the auxiliary forces can be obtained and is consistent with the theoretical one by the proposed assistance strategy. The H-Suit without the drive unit has little effect on the EMG signal of the lower limbs. In the powered condition, the H-Suit can delay the muscle fatigue of the lower limbs. The average rectified value (ARV) slope decreases and the median frequency (MNF) slope increases significantly. Wearing the H-Suit resulted in a significant reduction of the vastus lateralis effort, averaged over subjects and walking speeds, of 13.3 ± 2.1% (p = 2 × 10(−5)).
format Online
Article
Text
id pubmed-9227600
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-92276002022-06-25 Ergonomic Design and Performance Evaluation of H-Suit for Human Walking Zhang, Leiyu Jiao, Zhenxing He, Yandong Su, Peng Micromachines (Basel) Article A soft exoskeleton for the hip flexion, named H-Suit, is developed to improve the walking endurance of lower limbs, delay muscle fatigue and reduce the activation level of hip flexors. Based on the kinematics and biomechanics of the hip joints, the ergonomic design of the H-Suit system is clearly presented and the prototype was developed. The profile of the auxiliary forces is planned in the auxiliary range where the forces start at the minimum hip angle, reach the maximum (120 N) and end at 90% of each gait cycle. The desired displacements of the traction unit which consist of the natural and elastic displacements of the steel cables are obtained by the experimental method. An assistance strategy is proposed to track the profile of the auxiliary forces by dynamically adjusting the compensation displacement L(c) and the hold time Δt. The influences of the variables L(c) and Δt on the natural gaits and auxiliary forces have been revealed and analyzed. The real profile of the auxiliary forces can be obtained and is consistent with the theoretical one by the proposed assistance strategy. The H-Suit without the drive unit has little effect on the EMG signal of the lower limbs. In the powered condition, the H-Suit can delay the muscle fatigue of the lower limbs. The average rectified value (ARV) slope decreases and the median frequency (MNF) slope increases significantly. Wearing the H-Suit resulted in a significant reduction of the vastus lateralis effort, averaged over subjects and walking speeds, of 13.3 ± 2.1% (p = 2 × 10(−5)). MDPI 2022-05-25 /pmc/articles/PMC9227600/ /pubmed/35744439 http://dx.doi.org/10.3390/mi13060825 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zhang, Leiyu
Jiao, Zhenxing
He, Yandong
Su, Peng
Ergonomic Design and Performance Evaluation of H-Suit for Human Walking
title Ergonomic Design and Performance Evaluation of H-Suit for Human Walking
title_full Ergonomic Design and Performance Evaluation of H-Suit for Human Walking
title_fullStr Ergonomic Design and Performance Evaluation of H-Suit for Human Walking
title_full_unstemmed Ergonomic Design and Performance Evaluation of H-Suit for Human Walking
title_short Ergonomic Design and Performance Evaluation of H-Suit for Human Walking
title_sort ergonomic design and performance evaluation of h-suit for human walking
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9227600/
https://www.ncbi.nlm.nih.gov/pubmed/35744439
http://dx.doi.org/10.3390/mi13060825
work_keys_str_mv AT zhangleiyu ergonomicdesignandperformanceevaluationofhsuitforhumanwalking
AT jiaozhenxing ergonomicdesignandperformanceevaluationofhsuitforhumanwalking
AT heyandong ergonomicdesignandperformanceevaluationofhsuitforhumanwalking
AT supeng ergonomicdesignandperformanceevaluationofhsuitforhumanwalking