Cargando…
Accurate Mass Identification of an Interfering Water Adduct and Strategies in Development and Validation of an LC-MS/MS Method for Quantification of MPI8, a Potent SARS-CoV-2 Main Protease Inhibitor, in Rat Plasma in Pharmacokinetic Studies
MPI8, a peptidyl aldehyde, is a potent antiviral agent against coronavirus. Due to unique tri-peptide bonds and the formyl functional group, the bioassay of MPI8 in plasma was challenged by a strong interference from water MPI8. Using QTOF LC-MS/MS, we identified MPI8•H(2)O as the major interference...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9228185/ https://www.ncbi.nlm.nih.gov/pubmed/35745595 http://dx.doi.org/10.3390/ph15060676 |
_version_ | 1784734374249365504 |
---|---|
author | Wang, Yang Xie, Huan Alugubelli, Yugendar R. Ma, Yuying Xu, Shiqing Ma, Jing Liu, Wenshe R. Liang, Dong |
author_facet | Wang, Yang Xie, Huan Alugubelli, Yugendar R. Ma, Yuying Xu, Shiqing Ma, Jing Liu, Wenshe R. Liang, Dong |
author_sort | Wang, Yang |
collection | PubMed |
description | MPI8, a peptidyl aldehyde, is a potent antiviral agent against coronavirus. Due to unique tri-peptide bonds and the formyl functional group, the bioassay of MPI8 in plasma was challenged by a strong interference from water MPI8. Using QTOF LC-MS/MS, we identified MPI8•H(2)O as the major interference form that co-existed with MPI8 in aqueous and biological media. To avoid the resolution of MPI8 and MPI8•H(2)O observed on reverse phase columns, we found that a Kinetex hydrophilic interaction liquid chromatography (HILIC) column provided co-elution of both MPI8 and MPI8•H(2)O with a good single chromatographic peak and column retention of MPI8 which is suitable for quantification. Thus, a sensitive, specific, and reproducible LC-MS/MS method for the quantification of MPI8 in rat plasma was developed and validated using a triple QUAD LC-MS/MS. The chromatographic separation was achieved on a Kinetex HILIC column with a flow rate of 0.4 mL/min under gradient elution. The calibration curves were linear (r(2) > 0.99) over MPI8 concentrations from 0.5–500 ng/mL. The accuracy and precision are within acceptable guidance levels. The mean matrix effect and recovery were 139% and 73%, respectively. No significant degradation of MPI8 occurred under the experimental conditions. The method was successfully applied to a pharmacokinetic study of MPI8 after administration of MPI8 sulfonate in rats. |
format | Online Article Text |
id | pubmed-9228185 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-92281852022-06-25 Accurate Mass Identification of an Interfering Water Adduct and Strategies in Development and Validation of an LC-MS/MS Method for Quantification of MPI8, a Potent SARS-CoV-2 Main Protease Inhibitor, in Rat Plasma in Pharmacokinetic Studies Wang, Yang Xie, Huan Alugubelli, Yugendar R. Ma, Yuying Xu, Shiqing Ma, Jing Liu, Wenshe R. Liang, Dong Pharmaceuticals (Basel) Article MPI8, a peptidyl aldehyde, is a potent antiviral agent against coronavirus. Due to unique tri-peptide bonds and the formyl functional group, the bioassay of MPI8 in plasma was challenged by a strong interference from water MPI8. Using QTOF LC-MS/MS, we identified MPI8•H(2)O as the major interference form that co-existed with MPI8 in aqueous and biological media. To avoid the resolution of MPI8 and MPI8•H(2)O observed on reverse phase columns, we found that a Kinetex hydrophilic interaction liquid chromatography (HILIC) column provided co-elution of both MPI8 and MPI8•H(2)O with a good single chromatographic peak and column retention of MPI8 which is suitable for quantification. Thus, a sensitive, specific, and reproducible LC-MS/MS method for the quantification of MPI8 in rat plasma was developed and validated using a triple QUAD LC-MS/MS. The chromatographic separation was achieved on a Kinetex HILIC column with a flow rate of 0.4 mL/min under gradient elution. The calibration curves were linear (r(2) > 0.99) over MPI8 concentrations from 0.5–500 ng/mL. The accuracy and precision are within acceptable guidance levels. The mean matrix effect and recovery were 139% and 73%, respectively. No significant degradation of MPI8 occurred under the experimental conditions. The method was successfully applied to a pharmacokinetic study of MPI8 after administration of MPI8 sulfonate in rats. MDPI 2022-05-27 /pmc/articles/PMC9228185/ /pubmed/35745595 http://dx.doi.org/10.3390/ph15060676 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Wang, Yang Xie, Huan Alugubelli, Yugendar R. Ma, Yuying Xu, Shiqing Ma, Jing Liu, Wenshe R. Liang, Dong Accurate Mass Identification of an Interfering Water Adduct and Strategies in Development and Validation of an LC-MS/MS Method for Quantification of MPI8, a Potent SARS-CoV-2 Main Protease Inhibitor, in Rat Plasma in Pharmacokinetic Studies |
title | Accurate Mass Identification of an Interfering Water Adduct and Strategies in Development and Validation of an LC-MS/MS Method for Quantification of MPI8, a Potent SARS-CoV-2 Main Protease Inhibitor, in Rat Plasma in Pharmacokinetic Studies |
title_full | Accurate Mass Identification of an Interfering Water Adduct and Strategies in Development and Validation of an LC-MS/MS Method for Quantification of MPI8, a Potent SARS-CoV-2 Main Protease Inhibitor, in Rat Plasma in Pharmacokinetic Studies |
title_fullStr | Accurate Mass Identification of an Interfering Water Adduct and Strategies in Development and Validation of an LC-MS/MS Method for Quantification of MPI8, a Potent SARS-CoV-2 Main Protease Inhibitor, in Rat Plasma in Pharmacokinetic Studies |
title_full_unstemmed | Accurate Mass Identification of an Interfering Water Adduct and Strategies in Development and Validation of an LC-MS/MS Method for Quantification of MPI8, a Potent SARS-CoV-2 Main Protease Inhibitor, in Rat Plasma in Pharmacokinetic Studies |
title_short | Accurate Mass Identification of an Interfering Water Adduct and Strategies in Development and Validation of an LC-MS/MS Method for Quantification of MPI8, a Potent SARS-CoV-2 Main Protease Inhibitor, in Rat Plasma in Pharmacokinetic Studies |
title_sort | accurate mass identification of an interfering water adduct and strategies in development and validation of an lc-ms/ms method for quantification of mpi8, a potent sars-cov-2 main protease inhibitor, in rat plasma in pharmacokinetic studies |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9228185/ https://www.ncbi.nlm.nih.gov/pubmed/35745595 http://dx.doi.org/10.3390/ph15060676 |
work_keys_str_mv | AT wangyang accuratemassidentificationofaninterferingwateradductandstrategiesindevelopmentandvalidationofanlcmsmsmethodforquantificationofmpi8apotentsarscov2mainproteaseinhibitorinratplasmainpharmacokineticstudies AT xiehuan accuratemassidentificationofaninterferingwateradductandstrategiesindevelopmentandvalidationofanlcmsmsmethodforquantificationofmpi8apotentsarscov2mainproteaseinhibitorinratplasmainpharmacokineticstudies AT alugubelliyugendarr accuratemassidentificationofaninterferingwateradductandstrategiesindevelopmentandvalidationofanlcmsmsmethodforquantificationofmpi8apotentsarscov2mainproteaseinhibitorinratplasmainpharmacokineticstudies AT mayuying accuratemassidentificationofaninterferingwateradductandstrategiesindevelopmentandvalidationofanlcmsmsmethodforquantificationofmpi8apotentsarscov2mainproteaseinhibitorinratplasmainpharmacokineticstudies AT xushiqing accuratemassidentificationofaninterferingwateradductandstrategiesindevelopmentandvalidationofanlcmsmsmethodforquantificationofmpi8apotentsarscov2mainproteaseinhibitorinratplasmainpharmacokineticstudies AT majing accuratemassidentificationofaninterferingwateradductandstrategiesindevelopmentandvalidationofanlcmsmsmethodforquantificationofmpi8apotentsarscov2mainproteaseinhibitorinratplasmainpharmacokineticstudies AT liuwensher accuratemassidentificationofaninterferingwateradductandstrategiesindevelopmentandvalidationofanlcmsmsmethodforquantificationofmpi8apotentsarscov2mainproteaseinhibitorinratplasmainpharmacokineticstudies AT liangdong accuratemassidentificationofaninterferingwateradductandstrategiesindevelopmentandvalidationofanlcmsmsmethodforquantificationofmpi8apotentsarscov2mainproteaseinhibitorinratplasmainpharmacokineticstudies |