Cargando…

Accurate Mass Identification of an Interfering Water Adduct and Strategies in Development and Validation of an LC-MS/MS Method for Quantification of MPI8, a Potent SARS-CoV-2 Main Protease Inhibitor, in Rat Plasma in Pharmacokinetic Studies

MPI8, a peptidyl aldehyde, is a potent antiviral agent against coronavirus. Due to unique tri-peptide bonds and the formyl functional group, the bioassay of MPI8 in plasma was challenged by a strong interference from water MPI8. Using QTOF LC-MS/MS, we identified MPI8•H(2)O as the major interference...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Yang, Xie, Huan, Alugubelli, Yugendar R., Ma, Yuying, Xu, Shiqing, Ma, Jing, Liu, Wenshe R., Liang, Dong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9228185/
https://www.ncbi.nlm.nih.gov/pubmed/35745595
http://dx.doi.org/10.3390/ph15060676
_version_ 1784734374249365504
author Wang, Yang
Xie, Huan
Alugubelli, Yugendar R.
Ma, Yuying
Xu, Shiqing
Ma, Jing
Liu, Wenshe R.
Liang, Dong
author_facet Wang, Yang
Xie, Huan
Alugubelli, Yugendar R.
Ma, Yuying
Xu, Shiqing
Ma, Jing
Liu, Wenshe R.
Liang, Dong
author_sort Wang, Yang
collection PubMed
description MPI8, a peptidyl aldehyde, is a potent antiviral agent against coronavirus. Due to unique tri-peptide bonds and the formyl functional group, the bioassay of MPI8 in plasma was challenged by a strong interference from water MPI8. Using QTOF LC-MS/MS, we identified MPI8•H(2)O as the major interference form that co-existed with MPI8 in aqueous and biological media. To avoid the resolution of MPI8 and MPI8•H(2)O observed on reverse phase columns, we found that a Kinetex hydrophilic interaction liquid chromatography (HILIC) column provided co-elution of both MPI8 and MPI8•H(2)O with a good single chromatographic peak and column retention of MPI8 which is suitable for quantification. Thus, a sensitive, specific, and reproducible LC-MS/MS method for the quantification of MPI8 in rat plasma was developed and validated using a triple QUAD LC-MS/MS. The chromatographic separation was achieved on a Kinetex HILIC column with a flow rate of 0.4 mL/min under gradient elution. The calibration curves were linear (r(2) > 0.99) over MPI8 concentrations from 0.5–500 ng/mL. The accuracy and precision are within acceptable guidance levels. The mean matrix effect and recovery were 139% and 73%, respectively. No significant degradation of MPI8 occurred under the experimental conditions. The method was successfully applied to a pharmacokinetic study of MPI8 after administration of MPI8 sulfonate in rats.
format Online
Article
Text
id pubmed-9228185
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-92281852022-06-25 Accurate Mass Identification of an Interfering Water Adduct and Strategies in Development and Validation of an LC-MS/MS Method for Quantification of MPI8, a Potent SARS-CoV-2 Main Protease Inhibitor, in Rat Plasma in Pharmacokinetic Studies Wang, Yang Xie, Huan Alugubelli, Yugendar R. Ma, Yuying Xu, Shiqing Ma, Jing Liu, Wenshe R. Liang, Dong Pharmaceuticals (Basel) Article MPI8, a peptidyl aldehyde, is a potent antiviral agent against coronavirus. Due to unique tri-peptide bonds and the formyl functional group, the bioassay of MPI8 in plasma was challenged by a strong interference from water MPI8. Using QTOF LC-MS/MS, we identified MPI8•H(2)O as the major interference form that co-existed with MPI8 in aqueous and biological media. To avoid the resolution of MPI8 and MPI8•H(2)O observed on reverse phase columns, we found that a Kinetex hydrophilic interaction liquid chromatography (HILIC) column provided co-elution of both MPI8 and MPI8•H(2)O with a good single chromatographic peak and column retention of MPI8 which is suitable for quantification. Thus, a sensitive, specific, and reproducible LC-MS/MS method for the quantification of MPI8 in rat plasma was developed and validated using a triple QUAD LC-MS/MS. The chromatographic separation was achieved on a Kinetex HILIC column with a flow rate of 0.4 mL/min under gradient elution. The calibration curves were linear (r(2) > 0.99) over MPI8 concentrations from 0.5–500 ng/mL. The accuracy and precision are within acceptable guidance levels. The mean matrix effect and recovery were 139% and 73%, respectively. No significant degradation of MPI8 occurred under the experimental conditions. The method was successfully applied to a pharmacokinetic study of MPI8 after administration of MPI8 sulfonate in rats. MDPI 2022-05-27 /pmc/articles/PMC9228185/ /pubmed/35745595 http://dx.doi.org/10.3390/ph15060676 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wang, Yang
Xie, Huan
Alugubelli, Yugendar R.
Ma, Yuying
Xu, Shiqing
Ma, Jing
Liu, Wenshe R.
Liang, Dong
Accurate Mass Identification of an Interfering Water Adduct and Strategies in Development and Validation of an LC-MS/MS Method for Quantification of MPI8, a Potent SARS-CoV-2 Main Protease Inhibitor, in Rat Plasma in Pharmacokinetic Studies
title Accurate Mass Identification of an Interfering Water Adduct and Strategies in Development and Validation of an LC-MS/MS Method for Quantification of MPI8, a Potent SARS-CoV-2 Main Protease Inhibitor, in Rat Plasma in Pharmacokinetic Studies
title_full Accurate Mass Identification of an Interfering Water Adduct and Strategies in Development and Validation of an LC-MS/MS Method for Quantification of MPI8, a Potent SARS-CoV-2 Main Protease Inhibitor, in Rat Plasma in Pharmacokinetic Studies
title_fullStr Accurate Mass Identification of an Interfering Water Adduct and Strategies in Development and Validation of an LC-MS/MS Method for Quantification of MPI8, a Potent SARS-CoV-2 Main Protease Inhibitor, in Rat Plasma in Pharmacokinetic Studies
title_full_unstemmed Accurate Mass Identification of an Interfering Water Adduct and Strategies in Development and Validation of an LC-MS/MS Method for Quantification of MPI8, a Potent SARS-CoV-2 Main Protease Inhibitor, in Rat Plasma in Pharmacokinetic Studies
title_short Accurate Mass Identification of an Interfering Water Adduct and Strategies in Development and Validation of an LC-MS/MS Method for Quantification of MPI8, a Potent SARS-CoV-2 Main Protease Inhibitor, in Rat Plasma in Pharmacokinetic Studies
title_sort accurate mass identification of an interfering water adduct and strategies in development and validation of an lc-ms/ms method for quantification of mpi8, a potent sars-cov-2 main protease inhibitor, in rat plasma in pharmacokinetic studies
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9228185/
https://www.ncbi.nlm.nih.gov/pubmed/35745595
http://dx.doi.org/10.3390/ph15060676
work_keys_str_mv AT wangyang accuratemassidentificationofaninterferingwateradductandstrategiesindevelopmentandvalidationofanlcmsmsmethodforquantificationofmpi8apotentsarscov2mainproteaseinhibitorinratplasmainpharmacokineticstudies
AT xiehuan accuratemassidentificationofaninterferingwateradductandstrategiesindevelopmentandvalidationofanlcmsmsmethodforquantificationofmpi8apotentsarscov2mainproteaseinhibitorinratplasmainpharmacokineticstudies
AT alugubelliyugendarr accuratemassidentificationofaninterferingwateradductandstrategiesindevelopmentandvalidationofanlcmsmsmethodforquantificationofmpi8apotentsarscov2mainproteaseinhibitorinratplasmainpharmacokineticstudies
AT mayuying accuratemassidentificationofaninterferingwateradductandstrategiesindevelopmentandvalidationofanlcmsmsmethodforquantificationofmpi8apotentsarscov2mainproteaseinhibitorinratplasmainpharmacokineticstudies
AT xushiqing accuratemassidentificationofaninterferingwateradductandstrategiesindevelopmentandvalidationofanlcmsmsmethodforquantificationofmpi8apotentsarscov2mainproteaseinhibitorinratplasmainpharmacokineticstudies
AT majing accuratemassidentificationofaninterferingwateradductandstrategiesindevelopmentandvalidationofanlcmsmsmethodforquantificationofmpi8apotentsarscov2mainproteaseinhibitorinratplasmainpharmacokineticstudies
AT liuwensher accuratemassidentificationofaninterferingwateradductandstrategiesindevelopmentandvalidationofanlcmsmsmethodforquantificationofmpi8apotentsarscov2mainproteaseinhibitorinratplasmainpharmacokineticstudies
AT liangdong accuratemassidentificationofaninterferingwateradductandstrategiesindevelopmentandvalidationofanlcmsmsmethodforquantificationofmpi8apotentsarscov2mainproteaseinhibitorinratplasmainpharmacokineticstudies