A Novel Temperature Drift Error Precise Estimation Model for MEMS Accelerometers Using Microstructure Thermal Analysis

Owing to the fact that the conventional Temperature Drift Error (TDE) precise estimation model for a MEMS accelerometer has incomplete Temperature-Correlated Quantities (TCQ) and inaccurate parameter identification to reduce its accuracy and real time, a novel TDE precise estimation model using micr...

Descripción completa

Detalles Bibliográficos
Autores principales: Qi, Bing, Shi, Shuaishuai, Zhao, Lin, Cheng, Jianhua
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9229977/
https://www.ncbi.nlm.nih.gov/pubmed/35744449
http://dx.doi.org/10.3390/mi13060835