Sustained dialysis with misplaced peritoneal dialysis catheter outside peritoneum: A case report

BACKGROUND: In patients undergoing peritoneal dialysis (PD), catheter dysfunction is a common complication. A misplaced catheter is one of the reasons contributing to its dysfunction. The present study aimed to describe a case of misplaced PD catheter with an unusual location of the catheter tip. CA...