Cargando…

Sustained dialysis with misplaced peritoneal dialysis catheter outside peritoneum: A case report

BACKGROUND: In patients undergoing peritoneal dialysis (PD), catheter dysfunction is a common complication. A misplaced catheter is one of the reasons contributing to its dysfunction. The present study aimed to describe a case of misplaced PD catheter with an unusual location of the catheter tip. CA...

Descripción completa

Detalles Bibliográficos
Autores principales: Shen, Quan-Quan, Behera, Tapas Ranjan, Chen, Liang-Liang, Attia, Doaa, Han, Fei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Baishideng Publishing Group Inc 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9294885/
https://www.ncbi.nlm.nih.gov/pubmed/35979298
http://dx.doi.org/10.12998/wjcc.v10.i19.6501
_version_ 1784749943246815232
author Shen, Quan-Quan
Behera, Tapas Ranjan
Chen, Liang-Liang
Attia, Doaa
Han, Fei
author_facet Shen, Quan-Quan
Behera, Tapas Ranjan
Chen, Liang-Liang
Attia, Doaa
Han, Fei
author_sort Shen, Quan-Quan
collection PubMed
description BACKGROUND: In patients undergoing peritoneal dialysis (PD), catheter dysfunction is a common complication. A misplaced catheter is one of the reasons contributing to its dysfunction. The present study aimed to describe a case of misplaced PD catheter with an unusual location of the catheter tip. CASE SUMMARY: A 61-year-old man undergoing PD for 4 years was investigated for progressive nausea and fatigue of 3 mo. Dialysis adequacy studies indicated inefficient dialysis. Imaging discovered that the PD catheter tip was mispositioned in the pelvic cavity with its tip outside the peritoneal cavity. Despite the dialysate accumulating outside the peritoneal cavity, the patient had not developed perineal or scrotal edema. The patient had experienced a sustainable prolonged dialysis efficacy in this case until the renal function deteriorated further in view of the poor dialysis outcome and worsening health condition. The patient was subsequently transitioned to hemodialysis. CONCLUSION: Proper placement of the catheter in the peritoneal cavity should always be confirmed and re-checked when necessary in patients undergoing PD to ensure dialytic adequacy.
format Online
Article
Text
id pubmed-9294885
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Baishideng Publishing Group Inc
record_format MEDLINE/PubMed
spelling pubmed-92948852022-08-16 Sustained dialysis with misplaced peritoneal dialysis catheter outside peritoneum: A case report Shen, Quan-Quan Behera, Tapas Ranjan Chen, Liang-Liang Attia, Doaa Han, Fei World J Clin Cases Case Report BACKGROUND: In patients undergoing peritoneal dialysis (PD), catheter dysfunction is a common complication. A misplaced catheter is one of the reasons contributing to its dysfunction. The present study aimed to describe a case of misplaced PD catheter with an unusual location of the catheter tip. CASE SUMMARY: A 61-year-old man undergoing PD for 4 years was investigated for progressive nausea and fatigue of 3 mo. Dialysis adequacy studies indicated inefficient dialysis. Imaging discovered that the PD catheter tip was mispositioned in the pelvic cavity with its tip outside the peritoneal cavity. Despite the dialysate accumulating outside the peritoneal cavity, the patient had not developed perineal or scrotal edema. The patient had experienced a sustainable prolonged dialysis efficacy in this case until the renal function deteriorated further in view of the poor dialysis outcome and worsening health condition. The patient was subsequently transitioned to hemodialysis. CONCLUSION: Proper placement of the catheter in the peritoneal cavity should always be confirmed and re-checked when necessary in patients undergoing PD to ensure dialytic adequacy. Baishideng Publishing Group Inc 2022-07-06 2022-07-06 /pmc/articles/PMC9294885/ /pubmed/35979298 http://dx.doi.org/10.12998/wjcc.v10.i19.6501 Text en ©The Author(s) 2022. Published by Baishideng Publishing Group Inc. All rights reserved. https://creativecommons.org/licenses/by-nc/4.0/This article is an open-access article that was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution NonCommercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial.
spellingShingle Case Report
Shen, Quan-Quan
Behera, Tapas Ranjan
Chen, Liang-Liang
Attia, Doaa
Han, Fei
Sustained dialysis with misplaced peritoneal dialysis catheter outside peritoneum: A case report
title Sustained dialysis with misplaced peritoneal dialysis catheter outside peritoneum: A case report
title_full Sustained dialysis with misplaced peritoneal dialysis catheter outside peritoneum: A case report
title_fullStr Sustained dialysis with misplaced peritoneal dialysis catheter outside peritoneum: A case report
title_full_unstemmed Sustained dialysis with misplaced peritoneal dialysis catheter outside peritoneum: A case report
title_short Sustained dialysis with misplaced peritoneal dialysis catheter outside peritoneum: A case report
title_sort sustained dialysis with misplaced peritoneal dialysis catheter outside peritoneum: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9294885/
https://www.ncbi.nlm.nih.gov/pubmed/35979298
http://dx.doi.org/10.12998/wjcc.v10.i19.6501
work_keys_str_mv AT shenquanquan sustaineddialysiswithmisplacedperitonealdialysiscatheteroutsideperitoneumacasereport
AT beheratapasranjan sustaineddialysiswithmisplacedperitonealdialysiscatheteroutsideperitoneumacasereport
AT chenliangliang sustaineddialysiswithmisplacedperitonealdialysiscatheteroutsideperitoneumacasereport
AT attiadoaa sustaineddialysiswithmisplacedperitonealdialysiscatheteroutsideperitoneumacasereport
AT hanfei sustaineddialysiswithmisplacedperitonealdialysiscatheteroutsideperitoneumacasereport