Cargando…

Sustained dialysis with misplaced peritoneal dialysis catheter outside peritoneum: A case report

BACKGROUND: In patients undergoing peritoneal dialysis (PD), catheter dysfunction is a common complication. A misplaced catheter is one of the reasons contributing to its dysfunction. The present study aimed to describe a case of misplaced PD catheter with an unusual location of the catheter tip. CA...

Descripción completa

Detalles Bibliográficos
Autores principales: Shen, Quan-Quan, Behera, Tapas Ranjan, Chen, Liang-Liang, Attia, Doaa, Han, Fei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Baishideng Publishing Group Inc 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9294885/
https://www.ncbi.nlm.nih.gov/pubmed/35979298
http://dx.doi.org/10.12998/wjcc.v10.i19.6501

Ejemplares similares