A case report of right cardiac ventricle perforation by uncontrolled embolization coil inserted for treating penile veno-occlusive dysfunction

Coil embolization (CE) is believed effective-safe for treating penile veno-occlusive dysfunction (VOD). From 2012 to 2016, refractory impotence prompted four men to seek further treatment, although they underwent six CEs elsewhere. Uncontrolled coils scattered along penile drainage veins including t...