Cargando…
A hook wire dislodged into the subglottic area as a rare complication following computed tomography-guided hook wire localization: a case report
BACKGROUND: Computed tomography-guided hook wire localization (CT-GHWL) was used to localize the small pulmonary nodules before video-assisted thoracic surgery (VATS). Its associated complications included hook wire dislodgement, pulmonary hemorrhage, and pneumothorax. This is the first report of a...