Anterior to Posterior Bone Plug Suture Tunnels Provide Optimal Biomechanics for Bone−Patellar Tendon−Bone Anterior Cruciate Ligament Graft
PURPOSE: To evaluate different bone−patellar tendon−bone (BPTB) plug suture configurations for pull through strength, stiffness, and elongation at failure in a biomechanical model of suspensory fixation. METHODS: Forty nonpaired, fresh-frozen human cadaveric BPTB allografts with an average age of 65...