Interference Screws Are Biomechanically Superior to Suture Anchors for Medial Patellofemoral Ligament Reconstruction: A Systematic Review and Meta-Analysis
PURPOSE: To systematically review the literature to evaluate the biomechanical properties of the interference screw (IS) versus suture anchor (SA) techniques for patellar and femoral fixation of medial patellofemoral ligament (MPFL) reconstruction. METHODS: A systematic review was performed by searc...