Cargando…

Dynamic Mass Balance Modeling for Chemical Distribution Over Time in In Vitro Systems With Repeated Dosing

As toxicologists and risk assessors move away from animal testing and more toward using in vitro models and biological modeling, it is necessary to produce tools to quantify the chemical distribution within the in vitro environment prior to extrapolating in vitro concentrations to human equivalent d...

Descripción completa

Detalles Bibliográficos
Autores principales: Bloch, Sherri, Arnot, Jon A., Kramer, Nynke I., Armitage, James M., Verner, Marc-André
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9441784/
https://www.ncbi.nlm.nih.gov/pubmed/36071822
http://dx.doi.org/10.3389/ftox.2022.911128
_version_ 1784782662330744832
author Bloch, Sherri
Arnot, Jon A.
Kramer, Nynke I.
Armitage, James M.
Verner, Marc-André
author_facet Bloch, Sherri
Arnot, Jon A.
Kramer, Nynke I.
Armitage, James M.
Verner, Marc-André
author_sort Bloch, Sherri
collection PubMed
description As toxicologists and risk assessors move away from animal testing and more toward using in vitro models and biological modeling, it is necessary to produce tools to quantify the chemical distribution within the in vitro environment prior to extrapolating in vitro concentrations to human equivalent doses. Although models predicting chemical distribution in vitro have been developed, very little has been done for repeated dosing scenarios, which are common in prolonged experiments where the medium needs to be refreshed. Failure to account for repeated dosing may lead to inaccurate estimations of exposure and introduce bias into subsequent in vitro to in vivo extrapolations. Our objectives were to develop a dynamic mass balance model for repeated dosing in in vitro systems; to evaluate model accuracy against experimental data; and to perform illustrative simulations to assess the impact of repeated doses on predicted cellular concentrations. A novel dynamic in vitro partitioning mass balance model (IV-MBM DP v1.0) was created based on the well-established fugacity approach. We parameterized and applied the dynamic mass balance model to single dose and repeat dosing scenarios, and evaluated the predicted medium and cellular concentrations against available empirical data. We also simulated repeated dosing scenarios for organic chemicals with a range of partitioning properties and compared the in vitro distributions over time. In single dose scenarios, for which only medium concentrations were available, simulated concentrations predicted measured concentrations with coefficients of determination (R (2)) of 0.85–0.89, mean absolute error within a factor of two and model bias of nearly one. Repeat dose scenario simulations displayed model bias <2 within the cell lysate, and ∼1.5-3 in the medium. The concordance between simulated and available experimental data supports the predictive capacity of the IV-MBM DP v1.0 tool, but further evaluation as empirical data becomes available is warranted, especially for cellular concentrations.
format Online
Article
Text
id pubmed-9441784
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-94417842022-09-06 Dynamic Mass Balance Modeling for Chemical Distribution Over Time in In Vitro Systems With Repeated Dosing Bloch, Sherri Arnot, Jon A. Kramer, Nynke I. Armitage, James M. Verner, Marc-André Front Toxicol Toxicology As toxicologists and risk assessors move away from animal testing and more toward using in vitro models and biological modeling, it is necessary to produce tools to quantify the chemical distribution within the in vitro environment prior to extrapolating in vitro concentrations to human equivalent doses. Although models predicting chemical distribution in vitro have been developed, very little has been done for repeated dosing scenarios, which are common in prolonged experiments where the medium needs to be refreshed. Failure to account for repeated dosing may lead to inaccurate estimations of exposure and introduce bias into subsequent in vitro to in vivo extrapolations. Our objectives were to develop a dynamic mass balance model for repeated dosing in in vitro systems; to evaluate model accuracy against experimental data; and to perform illustrative simulations to assess the impact of repeated doses on predicted cellular concentrations. A novel dynamic in vitro partitioning mass balance model (IV-MBM DP v1.0) was created based on the well-established fugacity approach. We parameterized and applied the dynamic mass balance model to single dose and repeat dosing scenarios, and evaluated the predicted medium and cellular concentrations against available empirical data. We also simulated repeated dosing scenarios for organic chemicals with a range of partitioning properties and compared the in vitro distributions over time. In single dose scenarios, for which only medium concentrations were available, simulated concentrations predicted measured concentrations with coefficients of determination (R (2)) of 0.85–0.89, mean absolute error within a factor of two and model bias of nearly one. Repeat dose scenario simulations displayed model bias <2 within the cell lysate, and ∼1.5-3 in the medium. The concordance between simulated and available experimental data supports the predictive capacity of the IV-MBM DP v1.0 tool, but further evaluation as empirical data becomes available is warranted, especially for cellular concentrations. Frontiers Media S.A. 2022-08-22 /pmc/articles/PMC9441784/ /pubmed/36071822 http://dx.doi.org/10.3389/ftox.2022.911128 Text en Copyright © 2022 Bloch, Arnot, Kramer, Armitage and Verner. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Toxicology
Bloch, Sherri
Arnot, Jon A.
Kramer, Nynke I.
Armitage, James M.
Verner, Marc-André
Dynamic Mass Balance Modeling for Chemical Distribution Over Time in In Vitro Systems With Repeated Dosing
title Dynamic Mass Balance Modeling for Chemical Distribution Over Time in In Vitro Systems With Repeated Dosing
title_full Dynamic Mass Balance Modeling for Chemical Distribution Over Time in In Vitro Systems With Repeated Dosing
title_fullStr Dynamic Mass Balance Modeling for Chemical Distribution Over Time in In Vitro Systems With Repeated Dosing
title_full_unstemmed Dynamic Mass Balance Modeling for Chemical Distribution Over Time in In Vitro Systems With Repeated Dosing
title_short Dynamic Mass Balance Modeling for Chemical Distribution Over Time in In Vitro Systems With Repeated Dosing
title_sort dynamic mass balance modeling for chemical distribution over time in in vitro systems with repeated dosing
topic Toxicology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9441784/
https://www.ncbi.nlm.nih.gov/pubmed/36071822
http://dx.doi.org/10.3389/ftox.2022.911128
work_keys_str_mv AT blochsherri dynamicmassbalancemodelingforchemicaldistributionovertimeininvitrosystemswithrepeateddosing
AT arnotjona dynamicmassbalancemodelingforchemicaldistributionovertimeininvitrosystemswithrepeateddosing
AT kramernynkei dynamicmassbalancemodelingforchemicaldistributionovertimeininvitrosystemswithrepeateddosing
AT armitagejamesm dynamicmassbalancemodelingforchemicaldistributionovertimeininvitrosystemswithrepeateddosing
AT vernermarcandre dynamicmassbalancemodelingforchemicaldistributionovertimeininvitrosystemswithrepeateddosing