Cargando…

Video Head Impulse Test (vHIT) Findings in Patients With Superior Semicircular Canal Dehiscence: A Case–Control Study

OBJECTIVE: To explore the usefulness of the responses of video head impulse testing (vHIT) in assessing symptomatic patients with superior semicircular canal dehiscence (SSCD). METHODS: This was a prospective case–control study performed in a tertiary skull base referral Centre in the UK. It include...

Descripción completa

Detalles Bibliográficos
Autores principales: Tikka, Theofano, Slim, Mohd Afiq Mohd, Gaggini, Margaret, Kontorinis, Georgios
Formato: Online Artículo Texto
Lenguaje:English
Publicado: European Academy of Otology and Neurotology and the Politzer Society 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9450086/
https://www.ncbi.nlm.nih.gov/pubmed/33893778
http://dx.doi.org/10.5152/JIAO.2021.8572