Cargando…
Validation, kinetic modeling, and test-retest reproducibility of [(18)F]SynVesT-1 for PET imaging of synaptic vesicle glycoprotein 2A in mice
Alterations in synaptic vesicle glycoprotein 2 A (SV2A) have been associated with several neuropsychiatric and neurodegenerative disorders. Therefore, SV2A positron emission tomography (PET) imaging may provide a unique tool to investigate synaptic density dynamics during disease progression and aft...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9536120/ https://www.ncbi.nlm.nih.gov/pubmed/35570828 http://dx.doi.org/10.1177/0271678X221101648 |
_version_ | 1784802921969352704 |
---|---|
author | Bertoglio, Daniele Zajicek, Franziska Lombaerde, Stef De Miranda, Alan Stroobants, Sigrid Wang, Yuchuan Dominguez, Celia Munoz-Sanjuan, Ignacio Bard, Jonathan Liu, Longbin Verhaeghe, Jeroen Staelens, Steven |
author_facet | Bertoglio, Daniele Zajicek, Franziska Lombaerde, Stef De Miranda, Alan Stroobants, Sigrid Wang, Yuchuan Dominguez, Celia Munoz-Sanjuan, Ignacio Bard, Jonathan Liu, Longbin Verhaeghe, Jeroen Staelens, Steven |
author_sort | Bertoglio, Daniele |
collection | PubMed |
description | Alterations in synaptic vesicle glycoprotein 2 A (SV2A) have been associated with several neuropsychiatric and neurodegenerative disorders. Therefore, SV2A positron emission tomography (PET) imaging may provide a unique tool to investigate synaptic density dynamics during disease progression and after therapeutic intervention. This study aims to extensively characterize the novel radioligand [(18)F]SynVesT-1 for preclinical applications. In C57Bl/6J mice (n = 39), we assessed the plasma profile of [(18)F]SynVesT-1, validated the use of a noninvasive image-derived input function (IDIF) compared to an arterial input function (AIF), performed a blocking study with levetiracetam (50 and 200 mg/kg, i.p.) to verify the specificity towards SV2A, examined kinetic models for volume of distribution (V(T)) quantification, and explored test-retest reproducibility of [(18)F]SynVesT-1 in the central nervous system (CNS). Plasma availability of [(18)F]SynVesT-1 decreased rapidly (13.4 ± 1.5% at 30 min post-injection). V(T) based on AIF and IDIF showed excellent agreement (r(2) = 0.95, p < 0.0001) and could be reliably estimated with a 60-min acquisition. The blocking study resulted in a complete blockade with no suitable reference region. Test-retest analysis indicated good reproducibility (mean absolute variability <10%). In conclusion, [(18)F]SynVesT-1 is selective for SV2A with optimal kinetics representing a candidate tool to quantify CNS synaptic density non-invasively. |
format | Online Article Text |
id | pubmed-9536120 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-95361202022-10-07 Validation, kinetic modeling, and test-retest reproducibility of [(18)F]SynVesT-1 for PET imaging of synaptic vesicle glycoprotein 2A in mice Bertoglio, Daniele Zajicek, Franziska Lombaerde, Stef De Miranda, Alan Stroobants, Sigrid Wang, Yuchuan Dominguez, Celia Munoz-Sanjuan, Ignacio Bard, Jonathan Liu, Longbin Verhaeghe, Jeroen Staelens, Steven J Cereb Blood Flow Metab Original Articles Alterations in synaptic vesicle glycoprotein 2 A (SV2A) have been associated with several neuropsychiatric and neurodegenerative disorders. Therefore, SV2A positron emission tomography (PET) imaging may provide a unique tool to investigate synaptic density dynamics during disease progression and after therapeutic intervention. This study aims to extensively characterize the novel radioligand [(18)F]SynVesT-1 for preclinical applications. In C57Bl/6J mice (n = 39), we assessed the plasma profile of [(18)F]SynVesT-1, validated the use of a noninvasive image-derived input function (IDIF) compared to an arterial input function (AIF), performed a blocking study with levetiracetam (50 and 200 mg/kg, i.p.) to verify the specificity towards SV2A, examined kinetic models for volume of distribution (V(T)) quantification, and explored test-retest reproducibility of [(18)F]SynVesT-1 in the central nervous system (CNS). Plasma availability of [(18)F]SynVesT-1 decreased rapidly (13.4 ± 1.5% at 30 min post-injection). V(T) based on AIF and IDIF showed excellent agreement (r(2) = 0.95, p < 0.0001) and could be reliably estimated with a 60-min acquisition. The blocking study resulted in a complete blockade with no suitable reference region. Test-retest analysis indicated good reproducibility (mean absolute variability <10%). In conclusion, [(18)F]SynVesT-1 is selective for SV2A with optimal kinetics representing a candidate tool to quantify CNS synaptic density non-invasively. SAGE Publications 2022-05-14 2022-10 /pmc/articles/PMC9536120/ /pubmed/35570828 http://dx.doi.org/10.1177/0271678X221101648 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Articles Bertoglio, Daniele Zajicek, Franziska Lombaerde, Stef De Miranda, Alan Stroobants, Sigrid Wang, Yuchuan Dominguez, Celia Munoz-Sanjuan, Ignacio Bard, Jonathan Liu, Longbin Verhaeghe, Jeroen Staelens, Steven Validation, kinetic modeling, and test-retest reproducibility of [(18)F]SynVesT-1 for PET imaging of synaptic vesicle glycoprotein 2A in mice |
title | Validation, kinetic modeling, and test-retest reproducibility of [(18)F]SynVesT-1 for PET imaging of synaptic vesicle glycoprotein 2A in mice |
title_full | Validation, kinetic modeling, and test-retest reproducibility of [(18)F]SynVesT-1 for PET imaging of synaptic vesicle glycoprotein 2A in mice |
title_fullStr | Validation, kinetic modeling, and test-retest reproducibility of [(18)F]SynVesT-1 for PET imaging of synaptic vesicle glycoprotein 2A in mice |
title_full_unstemmed | Validation, kinetic modeling, and test-retest reproducibility of [(18)F]SynVesT-1 for PET imaging of synaptic vesicle glycoprotein 2A in mice |
title_short | Validation, kinetic modeling, and test-retest reproducibility of [(18)F]SynVesT-1 for PET imaging of synaptic vesicle glycoprotein 2A in mice |
title_sort | validation, kinetic modeling, and test-retest reproducibility of [(18)f]synvest-1 for pet imaging of synaptic vesicle glycoprotein 2a in mice |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9536120/ https://www.ncbi.nlm.nih.gov/pubmed/35570828 http://dx.doi.org/10.1177/0271678X221101648 |
work_keys_str_mv | AT bertogliodaniele validationkineticmodelingandtestretestreproducibilityof18fsynvest1forpetimagingofsynapticvesicleglycoprotein2ainmice AT zajicekfranziska validationkineticmodelingandtestretestreproducibilityof18fsynvest1forpetimagingofsynapticvesicleglycoprotein2ainmice AT lombaerdestefde validationkineticmodelingandtestretestreproducibilityof18fsynvest1forpetimagingofsynapticvesicleglycoprotein2ainmice AT mirandaalan validationkineticmodelingandtestretestreproducibilityof18fsynvest1forpetimagingofsynapticvesicleglycoprotein2ainmice AT stroobantssigrid validationkineticmodelingandtestretestreproducibilityof18fsynvest1forpetimagingofsynapticvesicleglycoprotein2ainmice AT wangyuchuan validationkineticmodelingandtestretestreproducibilityof18fsynvest1forpetimagingofsynapticvesicleglycoprotein2ainmice AT dominguezcelia validationkineticmodelingandtestretestreproducibilityof18fsynvest1forpetimagingofsynapticvesicleglycoprotein2ainmice AT munozsanjuanignacio validationkineticmodelingandtestretestreproducibilityof18fsynvest1forpetimagingofsynapticvesicleglycoprotein2ainmice AT bardjonathan validationkineticmodelingandtestretestreproducibilityof18fsynvest1forpetimagingofsynapticvesicleglycoprotein2ainmice AT liulongbin validationkineticmodelingandtestretestreproducibilityof18fsynvest1forpetimagingofsynapticvesicleglycoprotein2ainmice AT verhaeghejeroen validationkineticmodelingandtestretestreproducibilityof18fsynvest1forpetimagingofsynapticvesicleglycoprotein2ainmice AT staelenssteven validationkineticmodelingandtestretestreproducibilityof18fsynvest1forpetimagingofsynapticvesicleglycoprotein2ainmice |