Cargando…

High-density thrombus and maximum transverse diameter on multi-spiral computed tomography angiography combine to predict abdominal aortic aneurysm rupture

OBJECTIVE: We attempted to measure maximum transverse diameter (MTD) of and CT values of ILT by using multi-spiral computed tomography angiography (MSCTA) to investigate the predictive value of MTD with different CT values of thrombus on the risk of AAA rupture. METHODS: Forty-five intact abdominal...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Heqian, Chen, Zhipeng, Tang, Chen, Fan, Haijian, Mai, Xiaoli, Cai, Jing, Qiao, Tong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9561396/
https://www.ncbi.nlm.nih.gov/pubmed/36247433
http://dx.doi.org/10.3389/fcvm.2022.951264