Thromboprophylaxis with unilateral pneumatic device led to less edema and blood loss compared to enoxaparin after knee arthroplasty: randomized trial
BACKGROUND: Pharmacological and mechanical thromboprophylaxis are frequently used together after total knee arthroplasty (TKA). Most studies in this context compare anticoagulants versus a combination of these drugs with an intermittent pneumatic compression device (IPCD). However, there is uncertai...