Identification of the Optimal Position of a Nasal Oxygen Cannula for Apneic Oxygenation: A Technical Simulation

Background: In a cannot-ventilate-cannot-intubate situation, careful preoxygenation with high FiO(2) allowing subsequent apneic oxygenation can be life-saving. The best position for an oxygen supply line within the human airway at which oxygen insufflation is more effective than standard preoxygenat...

Descripción completa

Detalles Bibliográficos
Autores principales: Wetsch, Wolfgang A., Schroeder, Daniel C., Herff, Susanne J., Böttiger, Bernd W., Wenzel, Volker, Herff, Holger
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9694476/
https://www.ncbi.nlm.nih.gov/pubmed/36431286
http://dx.doi.org/10.3390/jcm11226809