Visual Inspection System for Uncoupling Status of Control-Rod Drive Rod in Nuclear Reactor

Under some unexpected conditions, drive rods and control-rod assemblies may not be disconnected. If this situation is not detected, the control rod will be lifted out of the reactor core together with the upper reactor internals. This situation will seriously affect the follow-up work and reduce the...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Zhi, Hu, Jianqiang, Zhou, Zhangxiang, Wang, Jin, Zhou, Xianen, Zhu, Qing, Chen, Shaonan, Wang, Yaonan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9698628/
https://www.ncbi.nlm.nih.gov/pubmed/36433401
http://dx.doi.org/10.3390/s22228805