Cargando…

Interactive 3D Force/Torque Parameter Acquisition and Correlation Identification during Primary Trocar Insertion in Laparoscopic Abdominal Surgery: 5 Cases

Laparoscopic procedures have become indispensable in gastrointestinal surgery. As a minimally invasive process, it begins with primary trocar insertion. However, this step poses the threat of injuries to the gastrointestinal tract and blood vessels. As such, the comprehension of the insertion proces...

Descripción completa

Detalles Bibliográficos
Autores principales: Nillahoot, Nantida, Pillai, Branesh M., Sharma, Bibhu, Wilasrusmee, Chumpon, Suthakorn, Jackrit
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9698636/
https://www.ncbi.nlm.nih.gov/pubmed/36433567
http://dx.doi.org/10.3390/s22228970
_version_ 1784838870795288576
author Nillahoot, Nantida
Pillai, Branesh M.
Sharma, Bibhu
Wilasrusmee, Chumpon
Suthakorn, Jackrit
author_facet Nillahoot, Nantida
Pillai, Branesh M.
Sharma, Bibhu
Wilasrusmee, Chumpon
Suthakorn, Jackrit
author_sort Nillahoot, Nantida
collection PubMed
description Laparoscopic procedures have become indispensable in gastrointestinal surgery. As a minimally invasive process, it begins with primary trocar insertion. However, this step poses the threat of injuries to the gastrointestinal tract and blood vessels. As such, the comprehension of the insertion process is crucial to the development of robotic-assisted/automated surgeries. To sustain robotic development, this research aims to study the interactive force/torque (F/T) behavior between the trocar and the abdomen during the trocar insertion process. For force/torque (F/T) data acquisition, a trocar interfaced with a six-axis F/T sensor was used by surgeons for the insertion. The study was conducted during five abdominal hernia surgical cases in the Department of Surgery, Faculty of Medicine, Ramathibodi Hospital, Mahidol University. The real-time F/T data were further processed and analyzed. The fluctuation in the force/torque (F/T) parameter was significant, with peak force ranging from 16.83 N to 61.86 N and peak torque ranging from 0.552 Nm to 1.76 Nm. The force parameter was observed to positively correlate with procedural time, while torque was found to be negatively correlated. Although during the process a surgeon applied force and torque in multiple axes, for a robotic system, the push and turn motion in a single axis was observed to be sufficient. For minimal tissue damage in less procedural time, a system with low push force and high torque was observed to be advantageous. These understandings will eventually benefit the development of computer-assisted or robotics technology to improve the outcome of the primary trocar insertion procedure.
format Online
Article
Text
id pubmed-9698636
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96986362022-11-26 Interactive 3D Force/Torque Parameter Acquisition and Correlation Identification during Primary Trocar Insertion in Laparoscopic Abdominal Surgery: 5 Cases Nillahoot, Nantida Pillai, Branesh M. Sharma, Bibhu Wilasrusmee, Chumpon Suthakorn, Jackrit Sensors (Basel) Article Laparoscopic procedures have become indispensable in gastrointestinal surgery. As a minimally invasive process, it begins with primary trocar insertion. However, this step poses the threat of injuries to the gastrointestinal tract and blood vessels. As such, the comprehension of the insertion process is crucial to the development of robotic-assisted/automated surgeries. To sustain robotic development, this research aims to study the interactive force/torque (F/T) behavior between the trocar and the abdomen during the trocar insertion process. For force/torque (F/T) data acquisition, a trocar interfaced with a six-axis F/T sensor was used by surgeons for the insertion. The study was conducted during five abdominal hernia surgical cases in the Department of Surgery, Faculty of Medicine, Ramathibodi Hospital, Mahidol University. The real-time F/T data were further processed and analyzed. The fluctuation in the force/torque (F/T) parameter was significant, with peak force ranging from 16.83 N to 61.86 N and peak torque ranging from 0.552 Nm to 1.76 Nm. The force parameter was observed to positively correlate with procedural time, while torque was found to be negatively correlated. Although during the process a surgeon applied force and torque in multiple axes, for a robotic system, the push and turn motion in a single axis was observed to be sufficient. For minimal tissue damage in less procedural time, a system with low push force and high torque was observed to be advantageous. These understandings will eventually benefit the development of computer-assisted or robotics technology to improve the outcome of the primary trocar insertion procedure. MDPI 2022-11-19 /pmc/articles/PMC9698636/ /pubmed/36433567 http://dx.doi.org/10.3390/s22228970 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Nillahoot, Nantida
Pillai, Branesh M.
Sharma, Bibhu
Wilasrusmee, Chumpon
Suthakorn, Jackrit
Interactive 3D Force/Torque Parameter Acquisition and Correlation Identification during Primary Trocar Insertion in Laparoscopic Abdominal Surgery: 5 Cases
title Interactive 3D Force/Torque Parameter Acquisition and Correlation Identification during Primary Trocar Insertion in Laparoscopic Abdominal Surgery: 5 Cases
title_full Interactive 3D Force/Torque Parameter Acquisition and Correlation Identification during Primary Trocar Insertion in Laparoscopic Abdominal Surgery: 5 Cases
title_fullStr Interactive 3D Force/Torque Parameter Acquisition and Correlation Identification during Primary Trocar Insertion in Laparoscopic Abdominal Surgery: 5 Cases
title_full_unstemmed Interactive 3D Force/Torque Parameter Acquisition and Correlation Identification during Primary Trocar Insertion in Laparoscopic Abdominal Surgery: 5 Cases
title_short Interactive 3D Force/Torque Parameter Acquisition and Correlation Identification during Primary Trocar Insertion in Laparoscopic Abdominal Surgery: 5 Cases
title_sort interactive 3d force/torque parameter acquisition and correlation identification during primary trocar insertion in laparoscopic abdominal surgery: 5 cases
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9698636/
https://www.ncbi.nlm.nih.gov/pubmed/36433567
http://dx.doi.org/10.3390/s22228970
work_keys_str_mv AT nillahootnantida interactive3dforcetorqueparameteracquisitionandcorrelationidentificationduringprimarytrocarinsertioninlaparoscopicabdominalsurgery5cases
AT pillaibraneshm interactive3dforcetorqueparameteracquisitionandcorrelationidentificationduringprimarytrocarinsertioninlaparoscopicabdominalsurgery5cases
AT sharmabibhu interactive3dforcetorqueparameteracquisitionandcorrelationidentificationduringprimarytrocarinsertioninlaparoscopicabdominalsurgery5cases
AT wilasrusmeechumpon interactive3dforcetorqueparameteracquisitionandcorrelationidentificationduringprimarytrocarinsertioninlaparoscopicabdominalsurgery5cases
AT suthakornjackrit interactive3dforcetorqueparameteracquisitionandcorrelationidentificationduringprimarytrocarinsertioninlaparoscopicabdominalsurgery5cases