Cargando…

Comparison of three methods of EPR retrospective dosimetry in watch glass

In this article we present results of our follow-up studies of samples of watch glass obtained and examined within a framework of international intercomparison dosimetry project RENEB ILC 2021. We present three methods of dose reconstruction based on EPR measurements of these samples: calibration me...

Descripción completa

Detalles Bibliográficos
Autores principales: Marciniak, Agnieszka, Juniewicz, Małgorzata, Ciesielski, Bartłomiej, Prawdzik-Dampc, Anita, Karczewski, Jakub
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9714545/
https://www.ncbi.nlm.nih.gov/pubmed/36466521
http://dx.doi.org/10.3389/fpubh.2022.1063769