Cargando…
Comparison of three methods of EPR retrospective dosimetry in watch glass
In this article we present results of our follow-up studies of samples of watch glass obtained and examined within a framework of international intercomparison dosimetry project RENEB ILC 2021. We present three methods of dose reconstruction based on EPR measurements of these samples: calibration me...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9714545/ https://www.ncbi.nlm.nih.gov/pubmed/36466521 http://dx.doi.org/10.3389/fpubh.2022.1063769 |
_version_ | 1784842251862540288 |
---|---|
author | Marciniak, Agnieszka Juniewicz, Małgorzata Ciesielski, Bartłomiej Prawdzik-Dampc, Anita Karczewski, Jakub |
author_facet | Marciniak, Agnieszka Juniewicz, Małgorzata Ciesielski, Bartłomiej Prawdzik-Dampc, Anita Karczewski, Jakub |
author_sort | Marciniak, Agnieszka |
collection | PubMed |
description | In this article we present results of our follow-up studies of samples of watch glass obtained and examined within a framework of international intercomparison dosimetry project RENEB ILC 2021. We present three methods of dose reconstruction based on EPR measurements of these samples: calibration method (CM), added dose method (ADM) and added dose&heating method (ADHM). The study showed that the three methods of dose reconstruction gave reliable and similar results in 0.5–6.0 Gy dose range, with accuracy better than 10%. The ADHM is the only one applicable in a real scenario, when sample-specific background spectrum is not available; therefore, a positive verification of this method is important for future use of EPR dosimetry in glass in potential radiation accidents. |
format | Online Article Text |
id | pubmed-9714545 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-97145452022-12-02 Comparison of three methods of EPR retrospective dosimetry in watch glass Marciniak, Agnieszka Juniewicz, Małgorzata Ciesielski, Bartłomiej Prawdzik-Dampc, Anita Karczewski, Jakub Front Public Health Public Health In this article we present results of our follow-up studies of samples of watch glass obtained and examined within a framework of international intercomparison dosimetry project RENEB ILC 2021. We present three methods of dose reconstruction based on EPR measurements of these samples: calibration method (CM), added dose method (ADM) and added dose&heating method (ADHM). The study showed that the three methods of dose reconstruction gave reliable and similar results in 0.5–6.0 Gy dose range, with accuracy better than 10%. The ADHM is the only one applicable in a real scenario, when sample-specific background spectrum is not available; therefore, a positive verification of this method is important for future use of EPR dosimetry in glass in potential radiation accidents. Frontiers Media S.A. 2022-11-17 /pmc/articles/PMC9714545/ /pubmed/36466521 http://dx.doi.org/10.3389/fpubh.2022.1063769 Text en Copyright © 2022 Marciniak, Juniewicz, Ciesielski, Prawdzik-Dampc and Karczewski. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Public Health Marciniak, Agnieszka Juniewicz, Małgorzata Ciesielski, Bartłomiej Prawdzik-Dampc, Anita Karczewski, Jakub Comparison of three methods of EPR retrospective dosimetry in watch glass |
title | Comparison of three methods of EPR retrospective dosimetry in watch glass |
title_full | Comparison of three methods of EPR retrospective dosimetry in watch glass |
title_fullStr | Comparison of three methods of EPR retrospective dosimetry in watch glass |
title_full_unstemmed | Comparison of three methods of EPR retrospective dosimetry in watch glass |
title_short | Comparison of three methods of EPR retrospective dosimetry in watch glass |
title_sort | comparison of three methods of epr retrospective dosimetry in watch glass |
topic | Public Health |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9714545/ https://www.ncbi.nlm.nih.gov/pubmed/36466521 http://dx.doi.org/10.3389/fpubh.2022.1063769 |
work_keys_str_mv | AT marciniakagnieszka comparisonofthreemethodsofeprretrospectivedosimetryinwatchglass AT juniewiczmałgorzata comparisonofthreemethodsofeprretrospectivedosimetryinwatchglass AT ciesielskibartłomiej comparisonofthreemethodsofeprretrospectivedosimetryinwatchglass AT prawdzikdampcanita comparisonofthreemethodsofeprretrospectivedosimetryinwatchglass AT karczewskijakub comparisonofthreemethodsofeprretrospectivedosimetryinwatchglass |