Cargando…

Comparison of three methods of EPR retrospective dosimetry in watch glass

In this article we present results of our follow-up studies of samples of watch glass obtained and examined within a framework of international intercomparison dosimetry project RENEB ILC 2021. We present three methods of dose reconstruction based on EPR measurements of these samples: calibration me...

Descripción completa

Detalles Bibliográficos
Autores principales: Marciniak, Agnieszka, Juniewicz, Małgorzata, Ciesielski, Bartłomiej, Prawdzik-Dampc, Anita, Karczewski, Jakub
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9714545/
https://www.ncbi.nlm.nih.gov/pubmed/36466521
http://dx.doi.org/10.3389/fpubh.2022.1063769
_version_ 1784842251862540288
author Marciniak, Agnieszka
Juniewicz, Małgorzata
Ciesielski, Bartłomiej
Prawdzik-Dampc, Anita
Karczewski, Jakub
author_facet Marciniak, Agnieszka
Juniewicz, Małgorzata
Ciesielski, Bartłomiej
Prawdzik-Dampc, Anita
Karczewski, Jakub
author_sort Marciniak, Agnieszka
collection PubMed
description In this article we present results of our follow-up studies of samples of watch glass obtained and examined within a framework of international intercomparison dosimetry project RENEB ILC 2021. We present three methods of dose reconstruction based on EPR measurements of these samples: calibration method (CM), added dose method (ADM) and added dose&heating method (ADHM). The study showed that the three methods of dose reconstruction gave reliable and similar results in 0.5–6.0 Gy dose range, with accuracy better than 10%. The ADHM is the only one applicable in a real scenario, when sample-specific background spectrum is not available; therefore, a positive verification of this method is important for future use of EPR dosimetry in glass in potential radiation accidents.
format Online
Article
Text
id pubmed-9714545
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-97145452022-12-02 Comparison of three methods of EPR retrospective dosimetry in watch glass Marciniak, Agnieszka Juniewicz, Małgorzata Ciesielski, Bartłomiej Prawdzik-Dampc, Anita Karczewski, Jakub Front Public Health Public Health In this article we present results of our follow-up studies of samples of watch glass obtained and examined within a framework of international intercomparison dosimetry project RENEB ILC 2021. We present three methods of dose reconstruction based on EPR measurements of these samples: calibration method (CM), added dose method (ADM) and added dose&heating method (ADHM). The study showed that the three methods of dose reconstruction gave reliable and similar results in 0.5–6.0 Gy dose range, with accuracy better than 10%. The ADHM is the only one applicable in a real scenario, when sample-specific background spectrum is not available; therefore, a positive verification of this method is important for future use of EPR dosimetry in glass in potential radiation accidents. Frontiers Media S.A. 2022-11-17 /pmc/articles/PMC9714545/ /pubmed/36466521 http://dx.doi.org/10.3389/fpubh.2022.1063769 Text en Copyright © 2022 Marciniak, Juniewicz, Ciesielski, Prawdzik-Dampc and Karczewski. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Public Health
Marciniak, Agnieszka
Juniewicz, Małgorzata
Ciesielski, Bartłomiej
Prawdzik-Dampc, Anita
Karczewski, Jakub
Comparison of three methods of EPR retrospective dosimetry in watch glass
title Comparison of three methods of EPR retrospective dosimetry in watch glass
title_full Comparison of three methods of EPR retrospective dosimetry in watch glass
title_fullStr Comparison of three methods of EPR retrospective dosimetry in watch glass
title_full_unstemmed Comparison of three methods of EPR retrospective dosimetry in watch glass
title_short Comparison of three methods of EPR retrospective dosimetry in watch glass
title_sort comparison of three methods of epr retrospective dosimetry in watch glass
topic Public Health
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9714545/
https://www.ncbi.nlm.nih.gov/pubmed/36466521
http://dx.doi.org/10.3389/fpubh.2022.1063769
work_keys_str_mv AT marciniakagnieszka comparisonofthreemethodsofeprretrospectivedosimetryinwatchglass
AT juniewiczmałgorzata comparisonofthreemethodsofeprretrospectivedosimetryinwatchglass
AT ciesielskibartłomiej comparisonofthreemethodsofeprretrospectivedosimetryinwatchglass
AT prawdzikdampcanita comparisonofthreemethodsofeprretrospectivedosimetryinwatchglass
AT karczewskijakub comparisonofthreemethodsofeprretrospectivedosimetryinwatchglass