Cooling Subgrade Effectiveness by L-Shaped Two-Phase Closed Thermosyphons with Different Inclination Angles and XPS Insulation Boards in Permafrost Regions
This study focused on the coupling heat transfer mechanism and the cooling efficiency of L-shaped two-phase closed thermosyphons (L-shaped TPCTs) in the wide subgrade of permafrost regions. Considering the fact that time–space dynamics change the effects of the air temperature, wind speed, and geote...